Inspection Status: Not Ready

Inspection History: COT - HCPL - Plumbing Above Ceiling

Permit Number - TC-COM-1223-02905

Inspection Description - COT - HCPL - Plumbing Above Ceiling

Inspection Status - Not Ready

Date Description Inspector Results Comments
04/30/2024 COT - HCPL - Plumbing Above Ceiling Not Ready
06/27/2024 COT - HCPL - Plumbing Above Ceiling Re-inspection required 6/27/24: copper piping shall not make contact with dissimilar metals (MC cable making contact throughout, Makings contact at top plates throughout), properly support copper piping throughout, DWV not under test, properly support Flex duct throughout, properly support MC cable through (off of grid), ensure that all light fixtures and A/C diffusers are properly supported by seismic wiring.
07/15/2024 COT - HCPL - Plumbing Above Ceiling Passed