Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T21DV08145
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/15/2021 | INSP - INITIAL CODE ENFORCMENT | Approved | EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE UPPER PORTION OF THE GLULAM BEAM, THE BEAM IS DIMENSIONED AT 6" X 12" X 7'.6" THE BEAM IS SUPPORTED BY A 3" X 3" X 9 'STEEL POST, THE POST HAS A 3 INCH TOP PLATE WHICH STILL PROVIDE ADEQUATE SUPPORT TO THE GLULAM BEAM. THIS SUPPORT SYSTEM IS DESIGNED FOR A STEEL STAIRCASE WITH CONCRETE STEPS. THE DAMAGE LOCATION IS ON THE SECOND STORY NEXT TO UNIT 13208. STRUCTURE ENGINEER MAY BE REQUIRED |