Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - ENGR - Signage Final
Permit Number - T20OT00761
Inspection Description - COT - ENGR - Signage Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2021 | COT - ENGR - Signage Final | DROBERTS | Approved | Entered by DROBERT5 - |
12/14/2020 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - INSPECTOR - REQUIRES SPECIAL INSPECTIONS - DO NOT FINAL UNTIL FORM RETURNED TO STAFF WITH ENGINEER'S SEAL THANK YOU |
12/10/2020 | COT - ENGR - Signage Final | Hthrall | Approved | Entered by HTHRALL1 - RE: wall signs over 50 sqft each in Urban Overlay District (Main Gate) Permit: T20OT00761 AT: 947 N Park / The Parker Structural review approved provided engineered plans on 12/10/2020. Permit can be released. |
12/07/2020 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - 12/7/2020 - Main Gate UOD review for signs over 50 sqft completed by design professional, who recommended approval of design. |
12/07/2020 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - Resubmittal received 12/7/20 for engineering diagrams to be reviewed. |
11/19/2020 | COT - ENGR - Signage Final | Hthrall | Continued | Entered by HTHRALL1 - RE: Main Gate - UOD review / signs over 50 sqft. The Design Professional is reviewing the request for signs to exceed 50 square feet both in total at the property and individually, per 7A.10.2.B. chart, while that size is allowed for the zone / use - they must be compatible with the Main Gate Urban Overlay Zone development schematic. |
11/10/2020 | COT - ENGR - Signage Final | HThrall | Continued | Entered by HTHRALL1 - RE: sign review (wall signs) AT: 947 N Park Av (formerly Aspire, now the Parker) Use: multi-family residential tower (8 stories) Zone: UC-1 - on Main Gate Overlay Sign District: Pedestrian Business District - Park Ave Date: 11/10/2020 Reviewer: H. Thrall 1) Site is a multi-family residential project, 8 stories, located in the specially mapped Pedestrian Business District. 2) 7A.2.2. Interpretation of applicable sign standards is based on the special mapped district, then zone and use. 3) 7A.10.2.B also requires that any signage proposed over 50 square feet - either for an individual sign or for an entire site within a "U" zoned property must be reviewed by the underlying urban overlay. This site is within the Main Gate Urban Overlay District. 4) acknowledged street frontage dimensions shown on elevation views, please add the same to the site plan on sheet 5 5) National Electrical Code (NEC 600) & Outdoor Lighting Code (OLC Ch 4 & 5) A) remove note that lighting shall not exceed 200 NITS (that's for digital signs, not the type of sign here) B) add note for timer shut off curfew time of midnight (OLC) 6) Engineered plans required for mount of signs greater than 30' off the ground, and special inspection required for the mount. (UDC Sign standards 7A.4.5) Should the proposed signs be approved through the Main Gate review process, please provide the engineered plans for the attachment and have your engineer fill out the special inspection form for type of attachment and qualified special inspector https://www.tucsonaz.gov/files/pdsd/forms/Special_inspection_certificate.pdf 7) Sign staff are working with the special overlays staff for advisement on the applicable review process for the Main Gate UOD sign review. Please send revisions to Heather.Thrall@tucsonaz.gov |