Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit: T19CM03789

Parcel: 12404098A


Addresses:

947 N PARK AV

Inspection Status: Approved

Inspection History: STEM WALL/RETAINING WALL

Date Description Inspector Results Comments
07/27/2021 STEM WALL/RETAINING WALL Approved
10/20/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
10/19/2020 STEM WALL/RETAINING WALL Cancelled Canceled by contractor.
10/16/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled, will reschedule for after hours inspection on 18 October
10/15/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
10/12/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level 8M, swimming pool walls at GL: D.8-E/3-6. Ok to set forms and place concrete in progress areas.
10/09/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled. Will reschedule for 12 October
10/08/2020 STEM WALL/RETAINING WALL Partial Approval Level #8; Pour #2; Shear wall #1 at GL: E-E.7/8. Columns at GL: D.8/1; D.8/2; D/3; D/4; B/4; D.9/3; D/5; D/6; B/5; A/6; E.7/5; E.7/6; F.5/7; F.5;8; F.5/9; A/9; A/8; C/8. Ok to place concrete in progress areas.
10/07/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #8 Mezzanine Pour #2: Shear wall #5 at GL: F/3-3.9; Shear Walls #6-7 at GL: G-G.2/3-3.9. Columns at GL: H.5/2; H.5/1; H.1/1; H.1/2; G.2/1; G.2/2; F.7/1; F.7/2; F.4/2; F.4/1; E.6/1; E.6/2; F.2/4.4; F.4/3.9; G/4.4. Ok to place concrete in progress areas.
10/02/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Information for MEP scheduling.
10/01/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #8 Mezzanine: Shear wall #2 at GL: H.7-I.2/8; Shear wall #4 at GL: I/5-6; Shear wall #13 at GL: J/1-2. Columns at GL: E.5/9; D.5/9; K/9: K.7.8; J/7.8; G.6/7; H/6; J/4.2; J.7/4.2. Ok to place concrete in progress areas.
09/28/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #8; Pour #2; Shear wall #1 at GL: 8/E-E.7; Shear wall #3 at GL: E/5-6. Columns at GL: D/4.1; B/4; B/5; D/5; A/6; D/6; C/8; A/8; A/9; D.5/9; F.5/9; F.5/8; F.5/7; E.7/6; E.7/5. Ok to place concrete in progress areas.
09/25/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #8; Pour #2: Shear wall #5 at GL: F/3-4. Columns at GL: F.4/3.9; F.4/3; F.7/2; F.7/1; F.4/1; F.4/2; E.6/2; E.6/1; D.8/2; D.8/1; B/2; B/3; D.9/3; D.9/3.9; F.2/4.4. Ok to set forms and place concrete in progress areas.
09/22/2020 STEM WALL/RETAINING WALL Partial Approval 01010. Partial. Level #7; Pour#1; Shear wall #2 at GL: 8/H-I. Columns at GL: H/5.8; D.6/7; D.6/8; H.7/9; G.6/9; I.7/9; K/9; K/8; J/8; J.5/6; K.5/6; J.7/4.2; J/4.2; J/3.2; K/3.2; J.9/2. Ok to place concrete in progress areas.
09/22/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #8; Pour #2; Shear wall #4 at GL: I/5-6; Shear wall #13 at GL: J/1-2. Columns at GL: I.2/3.9; I.2/3; J.7;1; I.3/2; H.5/1; H.5/2; H.1/2; H.1/1; G.2/2; G.2/1; G.9/4.4; G/4.4. Ok to place concrete in progress areas.
09/15/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #7; Pour #1; Shear Wall #1 at GL: 8/E-E.7; Shear wall #3 at GL: E/5-5.9. Columns at GL: D.9/3.9; D/4; B/4; B/5; D/5; A/6; D/6; C/8; A/8; A/9; B.5/9; E.5/9; F.5/9; F.5/8; F.5/7; E.7/6; E.7/5. Ok to place concrete in progress areas.
09/11/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Will reschedule for 12 September (after hours inspection)
09/08/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #7; Pour #2; Section #2; Columns at GL: H/5.6; G.6/7; G.6/6; G.6/9; H.7/9; I.7/9; K/9; K/7.8; J/7.8; K/5.6; J/5.6; J.7/4.2; J/4.2; I.2/3.9; . Shear wall #2 at GL: 8/H.7-I.2; Shear wall #4 at GL: I/5-6. Ok to place forms and concrete.
09/03/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
09/01/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #6; Pour #1: Columns at GL: F.2/4.4; F.4/3.9; F.4/3; F.4/2; D.8/2; D.8/1; B/1; B/2; B/3; D/3; D.9/3; D.9/3.9. Shear wall #5 at GL: F/3-3.9; Shear wall #12 at GL: E.6/1-2. Ok to place concrete in progress areas.
08/31/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled will reschedule for 1 September.
08/28/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
08/27/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #6; Pour #2: Columns at GL: J/3.2; K/3.2; K/2: J.7/1; I/2.3; I/3.2; I/3.1; H.5/2; H.5/1; H.1/1; H.1/2; G.2/1; G.2/2; F.7/2; F.7/1. Shear Walls #9; 10; 11 at GL: G.6-H.1/3-4.9; Shear Walls 6; 7; 8 at GL: G-G.2/3-3.9; Shear wall #13 at GL: J/1-2. Ok to place concrete in progress areas.
08/26/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #6; Pour #1; Section #1 columns at GL: G.9/5.6; G.6/7; G.6/8; G.6/9; H.7/9; I.7/9; K/9; K/7.8; J/7.8; K/5.6; J/5.6; I.2/3.9; J/4.2; J.7/4.2. Shear wall #2 at GL: H.7-I.2/8; Shear wall #4 at I/5-6. Ok to place concrete in progress areas.
08/25/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled
08/21/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #5; Pour #2: Columns at GL: B/4; D/4; B/5; D/5; D/6; A/6; C/8; A/8; A/9; D.5/9; E.5/9; F.5/9; F.5/8; F.5/7.
Shear walls; Shear wall #1 at GL: 8/D.9-E.7; Shear wall #3 at GL: E/5-6; Shear wall #5 at GL: F/3-3.9; Shear wall #12 at GL: E.6/1-2. Ok to place concrete in progress areas.
08/20/2020 STEM WALL/RETAINING WALL Partial Approval Partial Level #5; Pour two North; columns at GL: 3.9/F.4; F.2/4.4; F.4/3; F.4/2; F.4/1; D.8/2; D.8/1; B/.09; B/2; B/3; D/3; D.9/3; D/3.9; E.7/5; E.7/6. Ok to set forms and place concrete in progress areas.
08/19/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Post Tension Cable System at Level #5; pour #2: GL: G-A/0.09-9. Ok to place concrete in progress areas.
08/18/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
08/14/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #5; Shear wall #13 at GL: J/1-2. Columns at GL: I.2/3; J/3.2; K/3.2; K/2; J.7/1; I.3/1; I.3/2; H.5/2; H.5/1; H.1/1; H.1/2; G.2/1; G.2/2; F.7/2. Ok to place concrete in progress areas.
08/12/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
08/10/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #4; Pour #2; Columns at GL: D/4.1; B/4.1; B/5; D/5; D/5.9; C/8; A/8; A/9; D.5/9; E.5/9; F.5/9; F.5/8; F.5/7; E.7/5.9. Shear Wall #1 at GL: E-E.7/8; Shear Wall #3 at GL: E/5-5.6. Ok to set forms and place concrete in progress areas.
08/07/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #4; Pour #2 Shear wall #5 at GL: F/3-3.9; Shear wall #12 at GL: E.6/1-2. Ok to place concrete in progress areas. Columns at GL: F.2/4.4; F.4/3.9; F.4/3; F.4/2; F.4/1; D.8/2; D.8/1; B/0.9; B/2; B/3; D/3; D.9/3; D.9/3.9. Ok to place concrete in progress areas.
08/06/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
08/05/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
08/04/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #4;Shear walls #6; 7; 8 at GL: G-G.2/3-3.9; Shear walls #9; 10; 11 at GL: J/1-2; G/1-3. Columns at GL: G/4.4; G.9/4.4; F.7/2; I.3/3; I.3/3.9.

Ok to place concrete in progress areas.
08/03/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #1; Pour #1: Columns at GL:G.2/1; G.2/2; H.1/1; H.1/2; I.3/1; I.3/2; J.7/1; K/2; K/3.2; J/3.2; H.5/1; H./2. Shear wall #2 at GL: H.7-I.2/7.8; shear wall #4 at GL: I/5-6. OK to place concrete in progress areas.
07/31/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Post Tension Cable System at Level #4; Pour #1; at GL: G-K/0.9-9. Ok to place concrete in progress areas.
07/29/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled. Will reschedule for 30 July.
07/28/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level 3. Shear wall at line E-5 thru 6, shear wall line 8-B.9 thru E.7

Columns at F.5-8.8, F.5-8, F.5-7, E.7-6, E.7-7.5, D-5, B-5, B-4, A-6, D-6, C-8, A-8, A-9, D.5-9, E.5-9.
07/27/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #3 Pour #2: Shear walls: #5 at GL: F/3-3.9; #12 at GL: E.6/1-2. Columns at GL: F.2/4.4; F.4/3.9; F.4/3; F.4/2; F.4/1; D.8/2; B/1; D.8/1; B/2; D/3; D.9/3.9; D.9/3; D/4; B/4
07/23/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #3; Shear walls #6; 7; 8 at GL:G-G.2/3-4; Shear Walls #9; 10; 11 at GL: G.6-H/3-4. Columns at GL: G.9/4.4; G/4.4; F.7/2. Ok to place concrete in progress areas.
07/22/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #3; Shear wall #13 at GL: J/1-2. Columns at GL: I.2/3; J/3.2; K/3.2; K/2; J.7/1; I.3/2; H.5/1; H.5/2; H.1/2; H.1/1; G.2/1; G.2/2; I.3/1;. Ok to place concrete in progress areas.
07/21/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #3; Columns at GL: H.7/9; I.7/9; G.6/9; K/9; K/7.8; J/7.8; K/5.6; J5.6; J/5.6: J/5.6; G.6/8; G.6/7; H/5.6; J/4.2; J.7/4.2; I.2/3.9. Shear wall #4 at GL:I/5-6; Shear wall #2 at Gl: H.7-I.2/8
07/20/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #3; Post Tension Cable system at GL: F.9-K/0.9-4. Ok to place concrete in progress areas.
07/17/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #2; columns T GL: B/2; D.8/3.9. Ok to place concrete in progress areas
07/14/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #2 columns at GL: F.4/3.9; F.4/3; F.4/2; F.4/1; F.7/2; D/3. Ok to place concrete in progress areas.
07/13/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Post tension cable system at Level #2; pour #242 at GL: A-G/3-3.9. Ok to place concrete in progress area. Columns at GL: F.7;2; E.7/1; G.9/4.4; G/4.4. Shear Walls #6; 7; 8 at GL: G-G.2/3-3.9. Shear walls #9; 10; 11 at GL: G.6-H/3-4. Ok to set forms and place concrete in progress areas.
07/10/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #2; Shear Walls at GL: #2 at I/8; #4 at I/5.6; #13 at J/1.2. Columns at GL: G.6/8; G.6/7; H/5.6; I.2/3.9; J/4.2; H.5/1; H.1/2; G.2/2; I.3/1; I./2; K/3.2; J/3.2; K/2; J.7/1; H.5/2; H.1/1. Ok to place concrete in progress areas.
07/09/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #2 Columns at GL: K/9; I.7/9; H.7/9; G.6/9; J/7.8; K/7.8; J/5.2; K/5.2. Ok to place concrete in progress areas.
07/08/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
07/07/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
07/02/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
07/01/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled, will reschedule for 2 July.
06/30/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled will reschedule for 1 July.
06/29/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
06/26/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Will schedule for after hours inspection for 27 June at 0700.
06/25/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
06/24/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Mezzanine level #1: Shear wall #1 at GL: D.9-E.7/8. Ok to place concrete in progress area.
06/23/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Mezzanine Level columns at GL: B/.09; B/2. Ok to place concrete in progress areas
06/22/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Mezzanine level #1; Columns at GL: J/8; J/3.6; D/5; D.5/9; D.9/3; E.5/9; G.6/8; B/5
06/19/2020 STEM WALL/RETAINING WALL Cancelled Canceled by contractor
06/17/2020 STEM WALL/RETAINING WALL Partial Approval Partial. GarGe Level #2; Columns at GL: F.4/3; D.3/9. Ok to place concrete in progress areas.
06/16/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled
06/11/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Level #2 Garage; Shear wall #11 at GL: G.6/4.1. Columns at GL: G.6/6; H.9/5; G/5; G/4; . Ok to place concrete in progress areas.
06/10/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #2; Shear wall #4 at GL: I/5-6. Columns at GL: H/1; I.3/1; H.7/9. Ok to place concrete in progress areas.
06/09/2020 STEM WALL/RETAINING WALL Partial Approval Partial. GarGe Level #2; Shear Walls #2 at GL; 8/I-H, #13 at GL: J/1-2..
Columns at GL: G.6/8; H/5-6; H.1/2; H.5/1; H.4/2; I.2/3.9; I.2/3; I.3/2; J.7/1. Ok to place concrete in progress areas.
06/08/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #2 Columns at GL: K/9; K/7.8; J/7.8; J/5.6; K/5.6; J/4.2; J/3.2; K3.2; K/2; H.7/9; G.6/9. Ok to set forms and place concrete in progress areas.
06/03/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled. Shear walls and deck not ready, rescheduled for 4 June.
06/02/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready (VRI) Contractor cancelled.
06/01/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
05/29/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #2; columns at GL: G.6/8.1; F.5/8.1; E.7/6
Ok to place concrete in progress areas.
05/26/2020 STEM WALL/RETAINING WALL Cancelled Not ready. Contractor canceled.
05/22/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
05/21/2020 STEM WALL/RETAINING WALL Partial Approval Partial (VRI) Garage Level #2; Shear walls #5 at GL,: F/3-4; Columns : 4 each C-2
Columns at GL: F.4/3; F.4/4; F.2/4; E.7/5. Ok to place concrete in progress areas.
05/20/2020 STEM WALL/RETAINING WALL Partial Approval Partial (VRI). Garage Level #2; Shear wall, #12 at GL: E.6/.9-2; Ramp will at GL. 6/I.2-E.7; Columns at GL: F.4/.9; F.7/1; F.4/2; F.7/2. Ok to place concrete in progress areas
05/19/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #2; Shear wall #1 at GL: 8/E-E.7; Shear wall #3/5-6. Columns at GL: F.2/4; B/1; B/2; D.8/2; F.5/6; F.5/5. Exterior perimeter wall at GL: 9/D.5-E.7. Ok to place concrete in progress areas.
05/18/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #1; shear wall #13 at GL: J/.9-2. Columns at GL: 3.9/F.4; J/5.6; D/6; D/3; D.9/3,9; D/5; D.8/2; D.9/3; B/4. Ok to place concrete in progress areas.
05/15/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Garage Level #1: Columns: C-5 at G/4; C-4 at J.7/4.2. Shear wall #2 at H.7-I.2/8. Ok tp place concrete in progress areas.
05/06/2020 STEM WALL/RETAINING WALL Partial Approval Partial. New sump pump wall added via an RFI; at GL: 8.1/D.9-E.5; #4 rebar at 12” on center. Ok to place concrete in progress areas.
05/05/2020 STEM WALL/RETAINING WALL Not ready for Inspection Not ready. Contractor cancelled.
05/04/2020 STEM WALL/RETAINING WALL Not ready for Inspection RVI Not ready. Contractor cancelled.
05/01/2020 STEM WALL/RETAINING WALL Not ready for Inspection RVI Not ready. Contractor cancelled.
04/30/2020 STEM WALL/RETAINING WALL Partial Approval Partial. Shear wall ((North) at GL: A/8-9. Ok to place concrete in progress area.
04/28/2020 STEM WALL/RETAINING WALL Partial Approval Sump drain walls at 4’ at GL: D-D.8/1-2. Column footings at GL: D.8/3; D/4.1; D/5. Ok to place concrete in progress areas.
04/02/2020 STEM WALL/RETAINING WALL Partial Approval Stem wall at crane area, GL: 5-6/G-G.6. Ok to place concrete in progress areas.

RVI
01/31/2020 STEM WALL/RETAINING WALL Partial Approval Proceeding with first installation of auger nails at East wall southside.
01/30/2020 STEM WALL/RETAINING WALL Partial Approval Proceeding with shock Crete
01/27/2020 STEM WALL/RETAINING WALL Partial Approval Subgrade I-beam column number 114 OK
01/24/2020 STEM WALL/RETAINING WALL Partial Approval Subgrade I-beam columns 106, 108, 110 OK.
01/23/2020 STEM WALL/RETAINING WALL Partial Approval Subgrade I-beam column 102, 104, 106 OK
01/22/2020 STEM WALL/RETAINING WALL Partial Approval Subgrade I-beam columns 96 and 98 OK.
01/21/2020 STEM WALL/RETAINING WALL Partial Approval Caissons and I-beam columns 97, 99, 101, 103, 105, 107, 109, 111, 113, 115 OK.
01/17/2020 STEM WALL/RETAINING WALL Not ready for Inspection
01/16/2020 STEM WALL/RETAINING WALL Partial Approval Caisons 122, 120, 118 ok to pour
01/15/2020 STEM WALL/RETAINING WALL Partial Approval West shoring wall caissons 124 and 126 ok.
01/14/2020 STEM WALL/RETAINING WALL Partial Approval Caissons P130, P132, P134, P136 ok
01/10/2020 STEM WALL/RETAINING WALL Partial Approval West wall temporary shoring (caisson footings and cages); 4:caisson footings and cages; #19-25:
01/09/2020 STEM WALL/RETAINING WALL Partial Approval Retaining West wall; 7 each 45’ caisson footings and cages at GL: 9/A-F.5. Ok to place concrete in progress areas.
01/08/2020 STEM WALL/RETAINING WALL Partial Approval Information only. Site walk through..