Permit: T18CM00946

Parcel: 11504498B


Addresses:

850 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T18CM00946

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2019 BUILDING - FINAL Approved
12/12/2019 BUILDING - FINAL Partial Approval REVIEW OF AIR BALANCE REPORT COMPLETED
11/14/2019 BUILDING - FINAL Partial Approval Spoke to project manager, Stephen Van Peek, he stated that all requested information was submitted to Lisa B.
STILL NEED TO CALL IN ENGINEERING INSPECTIONS
10/29/2019 BUILDING - FINAL Partial Approval Submit all changes, RFI's, as built plans and special inspection certifications.
10/17/2019 BUILDING - FINAL Partial Approval PENDING REVISIONS
10/10/2019 BUILDING - FINAL Partial Approval Upper garage; paint exposed PVC pipes, seal all openings to building on the north side garage wall, missing electrical cover. Lower garage; missing electrical box cover seal in Cocoa wall openings. Second floor; seal around all video cameras, missing electrical box cover. Fourth floor; missing dryer vent. Stairwell two, level five missing light, stairwell one paint exterior PVC pipes. Label all disconnects and condensers on roof.
08/15/2019 BUILDING - FINAL Partial Approval Pending other inspections and special inspections
08/07/2019 BUILDING - FINAL Partial Approval On site with Armando, open issues still not addressed. Still have openings in corridor walls and ceilings. There’s no separation between construction and public.
08/05/2019 BUILDING - FINAL Not ready for Inspection Will recall for 7 August.
08/02/2019 BUILDING - FINAL Partial Approval Owner to make application for TCO for Occupancy of staff for 5 August for approximately 3 personnel. VIP occupants would like to occupy on 12 August with full occupancy 15 August.
07/31/2019 BUILDING - FINAL Partial Approval Levels 2, 3 and 4 are complete. Lobby, office area and town houses are complete.

Missing drain covers under pool, no electric at pool deck, no electric at fitness center and yoga room. Parking garage not ready.
07/29/2019 BUILDING - FINAL Partial Approval Plumbing fixtures not installed, RTU units on roof missing thermostat wires, missing electrical switches and outlets, GFI’s not installed properly. Stopped inspection
07/25/2019 BUILDING - FINAL Not ready for Inspection Cancel by contractor
07/24/2019 BUILDING - FINAL Partial Approval ADA unit 316
07/23/2019 BUILDING - FINAL Not ready for Inspection Canceled by contractor
07/22/2019 BUILDING - FINAL Partial Approval Level 4 all HVAC unit have been installed.
07/19/2019 BUILDING - FINAL Partial Approval Units 401 thru 415, 417, 418. All units need to have air handler secured t wall.
Unit 416 not ready.
07/18/2019 BUILDING - FINAL Partial Approval OK for TCO - Furniture stocking only
07/16/2019 BUILDING - FINAL Not ready for Inspection not complete.
07/15/2019 BUILDING - FINAL Partial Approval Student rooms on Levels #2 and #3: except for rooms 217 and 218. Rooms inspected for application of a Temporary Certificate of Occupancy for the placement of furniture and furniture related equipment. Not for occupancy. Application may be made when all rooms on Levels #2 and #3 are completed and noted corrections have even effected.
07/12/2019 BUILDING - FINAL Partial Approval Level III, units number 301, 302, 303, 304, 305, 306, 307, 309, 310, 315, 317, 318, 314 and 313. Unit number 308. Exhaust fan not working, GFI at kitchen counter is not working. Unit 312, smoke detectors not properly working , disconnect for HVAC does not fully open. Unit number 316 is not ready Unit number 311 and 314, the bathroom GFI‘s are connected to the light and exhaust fan. The kitchen GFI‘s are not properly wired.
07/11/2019 BUILDING - FINAL Not ready for Inspection Not complete
07/10/2019 BUILDING - FINAL Not ready for Inspection not complete.
07/05/2019 BUILDING - FINAL Denied Secured air handler according to manufacturers installation instructions, electrical schedule should match electrical panel, caulk around toilet, remove dryers to inspect dryer vent label and water hammer arrester’s, permanently affixed room number two unit, label disconnects on roof. Stopped inspection.
02/14/2019 BUILDING - FINAL Not ready for Inspection Not complete enough