Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T18CM00946
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2019 | FRAMING | Approved | ||
| 06/14/2019 | FRAMING | Not ready for Inspection | not complete | |
| 06/13/2019 | FRAMING | Partial Approval | Yoga room Is ready for sheet rock. Computer room second layer of sheet rock, however missing fire caulk. | |
| 06/12/2019 | FRAMING | Partial Approval | Fifth floor public restroom. | |
| 06/11/2019 | FRAMING | Cancelled | Canceled by contractor | |
| 06/10/2019 | FRAMING | Partial Approval | 5th floor restrooms | |
| 05/22/2019 | FRAMING | Not ready for Inspection | Contractor cancelled. | |
| 05/21/2019 | FRAMING | Not ready for Inspection | contractor cancelled. | |
| 05/20/2019 | FRAMING | Cancelled | no work to inspect at this time | |
| 05/15/2019 | FRAMING | Not ready for Inspection | not complete | |
| 05/13/2019 | FRAMING | Partial Approval | Unit number 417 OK Unit number 416, dryer vent has too many bends, support dampers on three sides, seal off firewall. Unit number 418, support triple trusses, missing nails in triple trust hangers. |
|
| 05/10/2019 | FRAMING | Partial Approval | third-floor Corridor | |
| 05/09/2019 | FRAMING | Partial Approval | ||
| 05/08/2019 | FRAMING | Partial Approval | Unit number 415 | |
| 05/07/2019 | FRAMING | Not ready for Inspection | not complete | |
| 05/06/2019 | FRAMING | Partial Approval | townhouse unit number 111 and corridor on the second floor | |
| 05/03/2019 | FRAMING | Not ready for Inspection | Contractor cancelled. | |
| 05/01/2019 | FRAMING | Not ready for Inspection | ||
| 04/30/2019 | FRAMING | Partial Approval | Units number 411 and townhouse number 112. | |
| 04/29/2019 | FRAMING | Not ready for Inspection | Not completed enough | |
| 04/26/2019 | FRAMING | Partial Approval | Units number 412 and 413 | |
| 04/25/2019 | FRAMING | Partial Approval | Unit number 413 secured 3 inch pipes, support roof drains, missing fire caulk in firewall, Missing smoke detector boxes, | |
| 04/22/2019 | FRAMING | Partial Approval | Units number 404, 405 and 406. Unit 403 frame shower out to 2 x 6 not 2 x 4, unit 402 exhaust fan termination cut in half at termination. |
|
| 04/19/2019 | FRAMING | Partial Approval | Unit number 406 has plumbing lines feeding unit number. Seal off holes in top plate in mechanical room,405 to the kitchen and refrigerator. Unit 406 seal off holes in the top plate at mechanical room. Unit number 405 missing clamps on plumbing pipes on south wall, filling holes in firewall, install fire stop in mechanical room. |
|
| 04/18/2019 | FRAMING | Partial Approval | Units number 406, 407 and 408. Townhouse unit number 112. Back bitch on 3 inch double toilet pipe in east bedroom. 3 inch support missing in south bedroom. There is a 3 inch pipe in the stairwell ceiling, no one knows where it goes. Townhouse number 111 missing steel studs, relocate smoke detector in bedroom, secure studs on second-floor firewall, resecure water supply. Stop inspection |
|
| 04/17/2019 | FRAMING | Partial Approval | Units number 408, 409, and 410 | |
| 04/16/2019 | FRAMING | Not ready for Inspection | unit not complete | |
| 04/15/2019 | FRAMING | Partial Approval | Walked through unit 410 only. Fire caulk all holes in fire blocking | |
| 04/12/2019 | FRAMING | Partial Approval | Unit number 314, 316, and 317 | |
| 04/11/2019 | FRAMING | Partial Approval | Unit. Number 315 | |
| 04/09/2019 | FRAMING | Partial Approval | Units number 301, 312, 313 | |
| 04/08/2019 | FRAMING | Partial Approval | Unit number 211 | |
| 04/05/2019 | FRAMING | Partial Approval | Units number 305, 304, 303 and 302 | |
| 04/04/2019 | FRAMING | Partial Approval | Third-floor unit 309 and 310. Units number 307 and 308 require detail for fire damper in the mechanical room | |
| 04/01/2019 | FRAMING | Cancelled | canceled by contractor | |
| 03/28/2019 | FRAMING | Partial Approval | Units number 215, 217, 218 | |
| 03/28/2019 | FRAMING | Partial Approval | Units number 215, 217, 218. | |
| 03/27/2019 | FRAMING | Cancelled | Cancel by contractor | |
| 03/26/2019 | FRAMING | Not ready for Inspection | Not complete enough | |
| 03/25/2019 | FRAMING | Cancelled | canceled by the contractor. | |
| 03/22/2019 | FRAMING | Partial Approval | Second floor Corredor‘s, and stairwell roofing. | |
| 03/21/2019 | FRAMING | Denied | Unit number 213. Missing Firefox, missing plumbing supports, sheet rock screws it hat channel, steel post missing supports, missing fire damper assembly. Units number to 12 and 211 not ready. Not complete enough |
|
| 03/18/2019 | FRAMING | Denied | Secure all walls | |
| 03/15/2019 | FRAMING | Partial Approval | Missing H2.5 clips on north balcony, loose bolts on south west corner of balcony, missing screws and glue Lam saddle | |
| 03/13/2019 | FRAMING | Partial Approval | For unit 202,203 and 204 | |
| 03/11/2019 | FRAMING | Partial Approval | For unit 202, 203, 204 fire caulk all exterior penetrations, all line sets in washer and dryer vents. Land all wires in the panel box. | |
| 03/08/2019 | FRAMING | Not ready for Inspection | not complete enough | |
| 03/07/2019 | FRAMING | Denied | Unit number 205, missing horizontal blocking between units, missing fire caulk in top plate, missing pins and soul plate, missing kitchen peninsula | |
| 03/06/2019 | FRAMING | Partial Approval | For unit 206, 207 and 208 | |
| 03/05/2019 | FRAMING | Partial Approval | Unit number 209 is complete, Unit number 208 secure all flex duct install dryer duct secure plumbing distribution pipe and DWV’s. |
|
| 03/01/2019 | FRAMING | Not ready for Inspection | Not complete enough | |
| 02/14/2019 | FRAMING | Not ready for Inspection | Not complete enough | |
| 02/08/2019 | FRAMING | Not ready for Inspection | This was a courtesy walk for units 209 and 210 only | |
| 02/07/2019 | FRAMING | Partial Approval | First level of fire wall separating townhouses OK to cover. |