Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T18CM00946
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/31/2019 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 05/13/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 417 OK Unit number 416, dryer vent has too many bends, support dampers on three sides, seal off firewall. Unit number 418, support triple trusses, missing nails in triple trust hangers. |
|
| 05/10/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | third-floor Corridor | |
| 05/09/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | ||
| 05/08/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 415 | |
| 05/07/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | not complete | |
| 05/06/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | townhouse unit number 111 and corridor on the second floor | |
| 05/03/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | Contractor cancelled. | |
| 05/01/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | ||
| 04/30/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 411 and townhouse number 112. | |
| 04/29/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | Not completed enough | |
| 04/26/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 412 and 413 | |
| 04/25/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 413 secured 3 inch pipes, support roof drains, missing fire caulk in firewall, Missing smoke detector boxes, | |
| 04/24/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | unit number 403. Unit 401 has cut trusses above the north window, hole in firewall, clamps missing on plumbing pipes. Stop Inspection | |
| 04/22/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 404, 405 and 406. Unit 403 frame shower out to 2 x 6 not 2 x 4, unit 402 exhaust fan termination cut in half at termination. |
|
| 04/19/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 406 has plumbing lines feeding unit number. Seal off holes in top plate in mechanical room,405 to the kitchen and refrigerator. Unit 406 seal off holes in the top plate at mechanical room. Unit number 405 missing clamps on plumbing pipes on south wall, filling holes in firewall, install fire stop in mechanical room. |
|
| 04/18/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 406, 407 and 408. Townhouse unit number 112. Back bitch on 3 inch double toilet pipe in east bedroom. 3 inch support missing in south bedroom. There is a 3 inch pipe in the stairwell ceiling, no one knows where it goes. Townhouse number 111 missing steel studs, relocate smoke detector in bedroom, secure studs on second-floor firewall, resecure water supply. Stop inspection |
|
| 04/17/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 408, 409, and 410 | |
| 04/16/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | unit not complete | |
| 04/15/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | Already covered with waterproofing. Per Antonio, this has been checked by hitting from inside. Super will wait for return of Ernie, as he has checked during work progress. | |
| 04/12/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 314, 316, and 317 | |
| 04/11/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit Number 315 | |
| 04/09/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 301, 312, 313 | |
| 04/08/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit number 211 Westside exterior wall on the 3rd floor |
|
| 04/05/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 305, 304, 303 and 302 | |
| 04/04/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Third-floor unit 309 and 310. Units number 307 and 308 require detail for fire damper in the mechanical room | |
| 04/02/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Townhouse units. Not all stud screwed to sole plate. | |
| 04/01/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | canceled by contractor | |
| 03/28/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 215, 217, 218 | |
| 03/28/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 215, 217, 218. | |
| 03/27/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | Cancel by contractor | |
| 03/26/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | Not complete enough | |
| 03/25/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | canceled by the contractor. | |
| 03/21/2019 | EXT METAL CLIPS/EXT SHEATHING | Denied | Unit number 213. Missing Firefox, missing plumbing supports, sheet rock screws it hat channel, steel post missing supports, missing fire damper assembly. Units number to 12 and 211 not ready. Not complete enough |
|
| 03/20/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | North exterior shear wall on 4th floor. Also units 215 and 214 | |
| 03/18/2019 | EXT METAL CLIPS/EXT SHEATHING | Denied | Unit 215 is not approved. Missing bolts in glue Lam in bathroom header, also missing nails in Joyce hangers. Missing anchor bolts on sheer wall. Not all nuts are tight on anchor bolts | |
| 03/15/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | northside sheer walls and anchor bolts only line one from B to G second and third floor. | |
| 03/13/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit 212 and 213 complete; unit 201, tighten bolts on ledger board, repair holes in floor, repair over bored holes in 2x’s , seal off dead spaces. | |
| 03/11/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Line 1 columns G through J floors 23 and four. This is the north east corner. | |
| 03/08/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | not complete enough | |
| 03/07/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit 203 and 202 | |
| 03/06/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | For unit 206, 207 and 208 | |
| 03/06/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Four units 204 and 205; also on east wall of townhouse installed dens glass | |
| 03/05/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Unit 206 missing pins in sole plate, missing nuts on anchor bolts at washer dryer area, north wall and Southwall; Unit number 210, missing hole down, missing lag bolts in 4 x 4 steel, missing lag bolts on glue Lam saddle in courtyard Unit number 207,208, 209 are complete. |
|
| 02/25/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Fourth floor, line 7 columnG through J. Rose one through seven column J. | |
| 02/22/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Second-floor east side exterior wall. Third floor east wall and south east corner | |
| 02/20/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | Not complete enough | |
| 02/12/2019 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | canceled by contractor | |
| 01/29/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Level two all exterior walls OK to cover | |
| 01/25/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | East side units number 202 through 204, courtyard exterior and interior shear walls. Also exterior south side walls | |
| 01/23/2019 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | Units number 205 through 210, courtyard exterior and interior shear walls only. | |
| 01/11/2019 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | Not complete enough. |