Permit: T18CM00946

Parcel: 11504498B


Addresses:

850 E SPEEDWAY BL

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
07/16/2019 REINFORCED MASONRY PRE-GROUT Approved See foundation permit T18CM 00899
07/10/2019 REINFORCED MASONRY PRE-GROUT Partial Approval I will need to meet with the contractor to ensure all work is complete.
02/27/2019 REINFORCED MASONRY PRE-GROUT Partial Approval 4 foot wide 8 feet in height wall on northeast corner with clean outs.
02/13/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Exterior sheathing and straps on southside balconies
01/18/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Row A 4th lift, section 4F top out, basement level section 2E 3rd lift top out. Line 7 B thru H top out.
01/17/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Row B 4th lift, Row A 3rd lift, section 4F @ 11ft, basement level section 2E 2nd lift.
01/16/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Row B 3rd lift, Row A 2nd lift, section 4F 6’8” w/clean outs, Line 7 E thru J.
01/14/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Row B 2nd lift, Row A 1st lift, Row J line 1.5-4.1 1st lift.
01/11/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Row B first lift, Line 4 row A, Line7 B thru E, Line 7 row G to H. 5th lift.
01/10/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Line 4 row A, line 4 row E, line 7 row E through J. All are fourth lift
01/09/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Line 4 row A, line 4 row 3, Line 7 E through J, all our third lift
01/08/2019 REINFORCED MASONRY PRE-GROUT Not ready for Inspection Customer wanted a p.m. inspection but did not leave a message or a phone number to pass on that request
I will notify supervisor to try to accommodate
project manager asked if I could come back requesting a 1 to 2 PM inspection however I will be unable to be here at that time I’ll be on another inspection far west
01/08/2019 REINFORCED MASONRY PRE-GROUT Partial Approval CMU walls on level #1, at GL; A/4; H/7. OK to place grout
01/07/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Masonry on Gridline 7 from D through H OK to grout to 4 feet above finish floor.
Masonry on Gridline four from A to B in and from 5 to 4 OK to 4 feet above finish floor
01/03/2019 REINFORCED MASONRY PRE-GROUT Partial Approval wall line for, OK to grout at 14 1/2 feet
01/02/2019 REINFORCED MASONRY PRE-GROUT Partial Approval Wall line 4 OK to grout to 12 ft elevation
12/28/2018 REINFORCED MASONRY PRE-GROUT Partial Approval Line 4- B thru F 2nd lift. Line 7 - A to B and mech. Room, 5th lift.
12/18/2018 REINFORCED MASONRY PRE-GROUT Partial Approval A7 to E7 only
12/17/2018 REINFORCED MASONRY PRE-GROUT Partial Approval A7 to E7 And mechanical room, third lift
12/13/2018 REINFORCED MASONRY PRE-GROUT Partial Approval A7 to E7. and mechanical room, second left
12/11/2018 REINFORCED MASONRY PRE-GROUT Partial Approval Masonry walls at townhome area ok to grout to 16’
12/07/2018 REINFORCED MASONRY PRE-GROUT Partial Approval Masonry walls at south east corner OK to 12 feet. Northside OK to top of wall or finish floor.
12/05/2018 REINFORCED MASONRY PRE-GROUT Partial Approval Eastside masonry walls in townhouse area OK to grout to 8 feet.
12/04/2018 REINFORCED MASONRY PRE-GROUT Partial Approval East side townhome area masonry walls OK to 4 feet.