Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/20/2016 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
01/15/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | GRID 7 CMU 1ST LIFT 5'4"OK | |
12/23/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
12/22/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL AT GL: .5A/ .5-10 OK TO GROUT PROGRESS AREA | |
12/18/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL AT EAST ENTRY AREA TO SE RESTROOMS IN WING A, B, C OK TO COVER WALLS |
|
11/02/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL FOOTINGS; EAST-WEST; NORTH-SOUTH OF EAST PARKING LOT ENTRY AREA- APPROX 700' OF FOOTINGS: WING "A"- DOCK LEVELERS; NORTH SIDE; SOUTH SIDE 19 LEVELERS. OK TO POUR PROGRESS AREAS |
|
10/29/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/12/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
10/06/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/02/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TILT PANELS #130-133; 140-145, 297, 352--357 | |
10/01/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | PANEL # 112-129 #6 REBAR DOWELS FOR FOOTING PIN NOT IN PLACE (#4 BARS WERE USED IN ERROR-SEE DETAIL #126) IF #6 BARS ARE NOT PLACED PANELS TO BE DRILLED AND EPOXIED POUR TO BE WITNESSED BY SPECIAL INSPECTION NOTE: POUR AT OWN RISK |
|
09/24/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/17/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TILT PANELS #149-157 | |
09/16/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/15/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TILT PANELS # 161-174; 240-242 OK TO POUR PROGRESS AREA | |
09/10/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/09/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/09/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | MISSING LEDGERS FOR PANELS | |
09/03/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/03/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | WING "A" TILT PANELS: #'S 91-105, 281, 283, 284, 279, AND 107-112 - OK TO POUR | |
09/01/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/01/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | WING "A"; SOUTH AND WEST PANELS - #'S 174-194, 238, & 239 - OK TO POUR | |
08/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/27/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | WING "B" PANELS; 70-77, 81-90 PANEL #'S: 81 - NW CORNER -RE-TIE CORNER 82 - SE CORNER - RE-TIE #4 BARS 84 - ELECTRIC BOX (SOUTH) RE-TIE |
|
08/26/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/26/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | WING "B" TILT PANELS - 77-79; 203-205 - OK TO POUR | |
08/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/24/2015 | REINFORCED MASONRY PRE-GROUT | Partial Approval | "B" WING TILT PANELS - SEE ATTACHED CORRECTIONS #'S: 196-202, 204, 208-216, 285-289 "B" WING TILT PANEL CORRECTIONS: #196 - NE CORNER CLEARANCE, 197 - SE CORNER CLEARANCE, 198 - NE CORNER #4 TIE; 199 - SW AREA TIE; 201 - E REPLACE BENT REBAR (LONG); # 196 - 202 NEED WELD PLATES. # 204 - TIE REBAR AT E WELD PLATE; 213 NE CORNER #4 BAR CLEARANCE; 214 - E & SE CORNERS #4 BARS CLEARANCE, WEST WELD PLATE TIE REBAR. 286 - SW CORNER #6 REBAR - SHORT, 287 - WEST END #4 BAR RETIE |
|
08/13/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | TILT PANELS | |
08/13/2015 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | SITE WALL AT EAST ENTRY AREA APPROX 200 OK TO GROUT PROGRESS AREA |