Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T12DV06651
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2012 | INSP - INITIAL CODE ENFORCMENT | Approved | BUILDING 1 SITE INSPECTION WITH GERALD G. AND RICK S. SHOW POINTS OF ATTACHMENTS' HAS VERTICAL MOVEMENT UP TO AND OVER 1" AND OVER AT STAIRWELL. ANGLE IRON LIP ARE HOLING STAIRS, NO PLACE FOR AGS TO BE USED. IN CASE OF EMERGENCY A LOT OF LATERAL MOVEMENT. ATTEMPTS HAVE BEEN MADE TO PIECE PORTIONS OF LANDINGS TO PREVENT DETONATION OF LANDINGS I.E 2X8 BLOCKS UNDER LANDING AS NAILERS. BUILDING 3 MODIFICATIONS FOR 2ND LEVEL STAIRCASE TO INCLUDE SCABBING WITH IMPROPER LAGS OR THROUGH BOLTS. BUILDING 5 BEAM WELDS AT 2ND LEVEL FOR SUPPORT NOT ANCHORED, POSTS SCABBED TOGETHER TO HELP WITH SUPPORT AND LEFT. BUILDING 13 EXHIBITS SIMILAR CONDITION OF OTHER BUILDING. WITH LANDING DETERIORATED TO POINT OF WOOD 2X6 SCREWS BEING DISLODGED, RAILING SCREWS LODGED TRIP HAZARDS ON WOOD LANDINGS. |