Permit: T10EL00038

Parcel: 11941288A


Addresses:

1451 W AJO WY 02


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T10EL00038

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/13/2010 ELECTRIC - FINAL Approved IVRS - Inspection :*
07/08/2010 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) FINISH INSTALL DINNING LIGHT-BOX NOT RATED FOR FAN WEIGHT
2) FINISH 1 & 7 PREVIOUS INSPECTION
3) NEED CONNECTOR AT NEW HOOD
01/11/2010 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL SMOKE DETECTORS IN BEDROOMS PER INSTRUCTIONS
2) INSTALL MISSING WALL PLATE ON RANGE RECEPT
3) HAVE WIRES HANGING OUT OF WALL WHERE HOOD EXHAUST ? LOCATED
4) KITCHEN COUNTER RECEPTS TO BE GFI PROTECTED
5) UNIT NOT HABITABLE, NEEDS TO HAVE WORKING BATHROOM AND KITCHEN TO HAVE POWER TURNED ON
6) PROPERLY CONNECT CABLE TO WATER HEATER AND CONNECT FEEDER PLATE TO HEATER
7) CLOTHES CLOSET LIGHT TO BE 100 PERCENT ENCLOSED
8) RESCHEDULE WHEN COMPLETE