Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MAKE UP WATER HEATER VENT CORRECTLY, PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT FITTINGS 2) PROVIDE VACCUM BREAKER AT HOSE BIB AT PRESSURE RELIEF VALVE AREA 3) PROVIDE NIPPLE ON PRESSURE RELIEF VALVE WITH NO THREADS ON END 4) CUT TEMPERATURE AND PRESSURE RELIEF DRAIN TO PROVIDE 1" AIR GAP AT CATCH PLAN 5) PETITION OF APPEAL ON SITE |
|
| 04/21/2004 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection 0000*/ T&P TO BE RIDGID PIPED TO DAYLIGHT GRAVITY DRAIN OR PROVIDE PETITION OF APPEAL ON SITE WITH ALTERNATE FORM OF T&P RELIEF INSTALLATION. |