Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Closed
Type:
SINGLE FAMILY OTHER
Address NEW:
7650 E LAKESIDE DR
Apply Date:
04/19/2004
Applicant:
ARIZONA PLUMBING SERVICES, DBA SEARS,*C
Description:
REPLACE:WATER HEATER (APA) T04VL00124
Contractors:
  • ARIZONA PLUMBING SERVICES, DBA SEARS,*C

Outstanding Activity Conditions

Permit Number - T04PL00727
Permit Status: Closed
Permit Description: REPLACE:WATER HEATER (APA) T04VL00124
Total Outstanding Activity Conditions - 1
Date Name
04/19/2004 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Closed
Permit Number: T04PL00727
Permite Description: REPLACE:WATER HEATER (APA) T04VL00124
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
10/21/2005 PLUMBING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAKE UP WATER HEATER VENT CORRECTLY, PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT FITTINGS
2) PROVIDE VACCUM BREAKER AT HOSE BIB AT PRESSURE RELIEF VALVE AREA
3) PROVIDE NIPPLE ON PRESSURE RELIEF VALVE WITH NO THREADS ON END
4) CUT TEMPERATURE AND PRESSURE RELIEF DRAIN TO PROVIDE 1" AIR GAP AT CATCH PLAN
5) PETITION OF APPEAL ON SITE

Documents

File Name Document Type  
None DOCUMENTS VIEW