Case: T03DV00148

Parcel: 11903423B


Addresses:

402 W 44TH ST

Inspection Status: Compliance

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
04/02/2004 INSP - FOLLOW UP CODE ENFORCE Compliance VIOLATIONS ABATED
VISITED SITE WITH INSP. II RICK SALDATE, REMAINING VIOLATION, INSTALLATION OF HEAT PUMP & AC UNIT DONE UNDER PERMIT T04ME00049 FINALED ON 2/4/04. REPAIRS TO BASEMENT DONE UNDER COMBO PERMIT T03CM05913 & FINALED ON 3/23/04. OWNER HAS COMPLIED. CLOSE CASE
01/22/2004 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE, MET WITH OWNER & WALKED PROPERTY/ NEW ROOF HAS BEEN INSTALLED. CENTRAL HEATING AND ELECTRICAL UP-GRADE HAS BEEN COMPLETED. ELECTRICAL UP-GRADE HAS BEEN FINALED UNDER PERMIT T03EL02147 AND FINALED ON 10/30/03. BASEMENT IS BEING RENOVATED UNDER COMBO PERMIT T03CM05913 ISSUED ON 12/30/03. NEW WINDOW GLAZING THROUGHOUT STRUCTURE.
11/25/2003 INSP - FOLLOW UP CODE ENFORCE Correction Required MET WITH OWNERS (NEW) WENT OVER ALL VIOLATIONS PERTAINING TO ALL 3 UNITS. WALKED UNIT C FIRST, POINTED OUT ELECTRICAL SYSTEMS. GFI NOT WORKING PROPERLY, UNGROUNDED RECEPTACLES, UNPROTECTED ELECTRICAL CONDUCTED AND DETERIORATED ELECTRICAL CONDUCTORS. WEATHER PROOFING OF EXTERIOR DOOR, BROKEN WINDOWS. INSTALLATION OF FIRE RATED DOOR FOR SEPARATION OF HOT WATER STORAGE ROOM, INSTALLATION OF HIGH AND LOW VENTS FOR COMBUSTION AIR, COMBUSTION RELIEF. EXSISTING WALL FURNACE COULD BE KEPT IF HEATING CONTRACTOR SERVICES AND PASSES CO TEST OTHERWISE HEATING WILL BE REQUIRED FOR ALL HABITABLE ROOMS. OWNERS HAVE BEGUN REHAB OF STURCTURE, ALL EXSISTING CABINETS HAVE BEEN REMOVED, NEW CERAMIC TILE HAS BEEN INSTALLED THROUGHOUT STRUCTURE. ALL WALLS EXCEPT KITCHEN AREA HAVE BEEN RETEXTURIZED AND PAINTED. OWNER IS IN PROCESS OF HAVING ELECTRICAL CONTRACTOR SUBMIT BIDS TO REWORK ELECTRICAL FOR BOTH UNITS A & B. WALKED UNIT B WITH OWNERS, EXPLAINED STRUCTURE HAD BEEN A CARPORT ORIGINALLY AND WAS CONVERTED INTO A LIVING SPACE ILLEGALLY. ALSO WAS LACKING PERMANENT SOURCE OF HEATING APPL. MOST IMPORTANT WAS PROPERTY WAS NOT ZONED FOR 3 STRUCTURES AND WOULD HAVE TO APPLY FOR A VARIANCE THROUGH ZONING BEFORE DOING ANY REPAIRS. OWNER ASKED IF STRUCTURE COULD BE USED FOR STORAGE AREA, EXPLAINED THEY WOULD STILL BE REQUIRED TO SUBMIT PLANS FOR APPROVAL TO DSD AND HAVE INSPECTION DONE BY DSD INSPECTORS. WENT OVER ELECTRICAL AND PLUMBING ISSUES, EXPLAINED SEWER LINES, WERE NOT PROPERLY INSTALLED AND WOULD REQUIRE PERMITS. WORK SHOULD BE DONE BY QUALIFIED CONTRACTOR. WALKED STRUCTURE WITH OWNER, ENTERED BASEMENT, EXPLAINED TO OWNER DUE TO THE AMOUNT OF DETERIORATION OF ADOBE WALLS AND REMOVAL OF EXSISTING SHORING HAS CREATED A HAZARD CONDITION. BRACING SUPPORTS HAVE BUCKELED AND FLOOR JOIST ARE SAGGING, ELECTRICAL SYSTEM IS IN A DILAPIDATED STATE AND ILLEGAL SPLICES ARE EVIDENT THROUGHOUT BASEMENT AND MAIN STRUCTURE. SOME NEW WAER LINES HAVE BEEN INSTALLED AS WELL AS NEW SEWER PIPE CONNECTIONS FOR NEW TUB AND SHOWER ENCLOSURE ALL WATER LINES AND SEWER DRAIN HOOK UPS. ILLEGALLY CONVERTED LAUNDRY ROOM INTO LIVING SPACE HAS BEEN SEPARATED BY SEALING OFF WINDOW USED TO ENTER ROOM AT ONE TIME (TIME OF INSPECTION) EXPLAINED TO OWNER ANY MODIFICATIONS TO STRUCTURE WILL REQUIRE SUBMITTAL OF DRAWING FOR APPROVAL BY DSD AND SECURING OF PERMITS BEFORE MOVING FORWARD WITH REHAB OF STRUCTURE. PERMANENT SOURCE OF HEATING WILL BE REQUIRED PER EACH HABITABLE ROOMS ALSO WILL BE RECEIVING NOV. WITH IN THE NEXT WEEK. OWNER STATED THEY WILL STAY IN CONTACT AND WILL BE AWAITING N.O.V.'S.
07/18/2003 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE ON FOLLOW UP INSP. UNIT APPEARES TO HAVE HAD A FIRE IN SOUTH WEST BEDROOM. UNIT HAS BEEN BOARDED UP AND IS SECURED, NO UTILITIES TO UNITS A & C. UNIT C IS VACANT AND SECURED THIS TIME. CHAINS AND LOCKS ON BOTH GATES. WILL CONTACT OWNER AND REQUEST STATUS OF PROJECT. PICTURES WERE TAKEN.