Inspection Status: Approved
Inspection History: MOBILE HOME UNDERGROUND GAS
Permit Number - T01MH00162
Inspection Description - MOBILE HOME UNDERGROUND GAS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/29/2001 | MOBILE HOME UNDERGROUND GAS | Approved | IVRS - Inspection 0000* | |
03/22/2001 | MOBILE HOME UNDERGROUND GAS | Denied | IVRS - Inspection 0999* | |
03/20/2001 | MOBILE HOME UNDERGROUND GAS | Denied | 1) GAS PIPE ON TOP OF GROUND 2) NO FLEXABLE CONNECTOR 3) IMPROPER PLACEMENT OF DIELECTRIC UNIONS 4) IMPROPER GAUGE FOR GAS TEST 5) GAS LINE NOT BONDED TO GROUND 6) IMPROPER GAS TEST 7) FLOOR OF WATER HEATER COMPARTMENT NEEDS REPLACEMENT 8) EXHAUST VENTS NOT CONNECTED 9) COMBUSTION AIR VENTS BLOCKED |