Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01MH00162

Parcel: 140240250


Addresses:

1200 E BILBY RD #34


Inspection Status: Approved

Inspection History: MOBILE HOME UNDERGROUND GAS

Permit Number - T01MH00162

Inspection Description - MOBILE HOME UNDERGROUND GAS

Inspection Status - Approved

Date Description Inspector Results Comments
03/29/2001 MOBILE HOME UNDERGROUND GAS Approved IVRS - Inspection 0000*
03/22/2001 MOBILE HOME UNDERGROUND GAS Denied IVRS - Inspection 0999*
03/20/2001 MOBILE HOME UNDERGROUND GAS Denied 1) GAS PIPE ON TOP OF GROUND 2) NO FLEXABLE CONNECTOR 3) IMPROPER PLACEMENT OF DIELECTRIC UNIONS 4) IMPROPER GAUGE FOR GAS TEST 5) GAS LINE NOT BONDED TO GROUND
6) IMPROPER GAS TEST 7) FLOOR OF WATER HEATER COMPARTMENT NEEDS REPLACEMENT
8) EXHAUST VENTS NOT CONNECTED
9) COMBUSTION AIR VENTS BLOCKED