Inspection Status: Not Ready
Inspection History: Consultation SITE
Permit Number - DP22-0091
Inspection Description - Consultation SITE
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/30/2024 | Consultation SITE | Not Ready | Trees in front of building in lot area need to be properly staked. And remove nursery stakes. Trees along sidewalk at front are to close to 2nd floor and are growing up into,the ceiling. ADA parking slopes need to be fixed and no ADA signage is visible. 1/4” or more was evident in several areas of the sidewalks. Also fill all cracks that are a 1/4” or more. Gutter along front is needed at the extruded curb line. Bike racks need to be installed. Ramp going from building 2 to building one is an accessible path and the slope is 9%. Staircases at each end of the building are more than 3/8” of an inch out of compliance in the course of the run with the first step being a 4” step and the rest at 7”s |
|
11/04/2024 | Consultation SITE | Passed | Okay for Full C of O for Building 1 |