| 02/26/2025 | Consultation SITE | Partial Pass | inform the contractor that the drainage on the E. Side Park Avenue road there needs to be addressed the drainage cannot hit the sidewalk area either redesign it or find some other way to divert the water from hitting the sidewalk. The contractor also asked if they could store some of their equipment on the bottom floor of the parking area taking up two spaces and I agreed with it. They only be there for couple weeks. | |
| 04/21/2025 | Consultation SITE | Partial Pass | I spoke to the contractor on site over the phone. He would like to reschedule everything for next week. | |
| 05/13/2025 | Consultation SITE | Re-inspection required | 05/13/25, Van assessable space missing van sign. Van assessable Less than 5' between space and wall. Lower ramp was at 8.7% 8.33 required max. Space adjacent to ramp had a hump in the parking area. Loop at bottom of ADA rail missing. | |
| 07/11/2025 | Consultation SITE | Passed | All conditions from TCO have been corrected. |