Case Details

Status:

COMPLIAN

Type:

DILAPIDATED STRUCTURE

Entered Date:

06/26/2017

Applicant:

ANN M BOYCE

Description:

EXTERIOR BUILDING CODE VIOLATIONS

Case Violations

Case Number: T17DV02737
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Violations: 2
Violation Date Code Statue
06/27/2017 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
06/28/2017 NOTICE OF VIOLATION ISSUED

Outstanding Inspections

Case Number: T17DV02737
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
09/13/2017 NPO(DL)-DILAPIDATED STRUCTURE BIGMAN Follow-up inspection
09/13/2017 NPO - WORK WITHOUT PERMIT BIGMAN Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV02737
Case Description: DILAPIDATED STRUCTURE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/21/2017 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ONSITE INSPECTION OF BLDG. 10 EXTERIOR INSPECTION OF BUILDING 10, THIS BUILDING IS A 2 STORY BUILDING WITH 8 UNITS. THE BUILDING IS A CMU TYPE BUILDING. . THE FRONT OF THE BUILDING HAS AN OPEN PORCH WITH A STEEL FRAMED STAIRCASE WITH CONCRETE STEPS. THE REAR OF THE BUILDING HAS A WOOD FRAMED REAR CANTILEVER BALCONY WITH DECKING BOARDS AND A METAL RAILING. THIS WAS A VISUAL INSPECTION FROM THE GROUND FLOOR. BELOW ARE THE CODE VIOLATIONS DECKING BOARDS HAVE DETERIORATED AND ARE DAMAGED DUE TO WOOD ROT. THERE IS NO POSITIVE CONNECTION WITH THE CROSS BEAM AND POST METAL RAILINGS HAVE MISSING HARDWARE, PORTIONS OF THE RAILING HAVE EXCESSIVE RUST. THE FRAMED METAL STAIRCASE HAS SEVERE RUST IN AREAS WHICH SUPPORTS THE CONCRETE STEPS. THERE IS RUST ON THE STEEL POSTS WHICH SUPPORT THE ENTIRE FRONT PORCH STRUCTURE WHICH CONSIST OF THE MULTIPLE STAIRCASES. MULTIPLE FLOOR JOISTS HAVE SEVERE WOOD ROT DAMAGE.
09/13/2017 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved OWNER OBTAINED A PERMIT FOR REPAIRS TO BALCONIES AND WALKWAY AREA: T17CM02737

Completed Activity Special Conditions

Case Description - DILAPIDATED STRUCTURE
Case Number - T17DV02737
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/27/2017 CONTACTED IN PERSON
06/28/2017 CONTACTED BY MAILING