Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T17DV02735
Case Details
Entered Date:
06/26/2017
Applicant:
BOYCE ANN M 64% & AJDAR VENTUR LLC 17.5% & BOYCE
Description:
EXTERIOR BUILDING CODE VIOLATIONS
Case Violations
Case Number: T17DV02735
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 06/27/2017 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 06/27/2017 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T17DV02735
Case Status: COMPLIAN
Case Description: DILAPIDATED STRUCTURE
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/02/2017 | NPO(DL)-DILAPIDATED STRUCTURE | VINDIOLA | Follow-up inspection | |
| 08/02/2017 | NPO - WORK WITHOUT PERMIT | VINDIOLA | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV02735
Case Description: DILAPIDATED STRUCTURE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2017 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | ONSITE INSPECTION OF BLDG. 8 EXTERIOR INSPECTION OF BUILDING 8, THIS BUILDING IS A 2 STORY BUILDING WITH 4 UNITS. THE BUILDING IS A CMU TYPE BUILDING. . THE FRONT OF THE BUILDING HAS AN OPEN PORCH WITH A STEEL FRAMED STAIRCASE WITH CONCRETE STEPS. THE REAR OF THE BUILDING HAS A WOOD FRAMED REAR CANTILEVER BALCONY WITH DECKING BOARDS AND A METAL RAILING. THIS WAS A VISUAL INSPECTION FROM THE GROUND FLOOR. BELOW ARE THE CODE VIOLATIONS FRONT OF THE BUILDING DECKING BOARDS HAVE DETERIORATED AND ARE DAMAGED DUE TO WOOD ROT. RIM JOIST IS DAMAGED AND THERE'S A SECTION IS MISSING BETWEEN THE STAIRCASE AND DECK. MULTIPLE FLOOR JOISTS HAVE SEVERE WOOD ROT DAMAGE MULTIPLE BEAMS HAVE LOOSE HARDWARE. REAR OF THE BUILDING THE BALCONIES HAVE HEAVY DETERIORATION AND WOOD ROT DAMAGE TO THE DECKING BOARDS, THERE ARE BOARDS WHICH HAVE UPLIFTED DUE TO WRAP AND MISSING FASTENERS. ELECTRICAL JUNCTION BOX HAS MISSING COVER |
| 11/22/2017 | INSP - FOLLOW UP CODE ENFORCE | VINDIOLA | Approved | Arrived on site with TPD, owner and Inspector Bigman. Walked the property as a follow up and to bring TPD on board as to what is going on with this property. Owner states all permits have been pulled and issued for the repairs of each building. She has also secured a loan to complete the project and is working one building at a time. Code Enforcement will continue to work with owner and follow up on these cases. |
Completed Activity Special Conditions
Case Description - DILAPIDATED STRUCTURE
Case Number - T17DV02735
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/27/2017 | CONTACTED IN PERSON |
| 06/29/2017 | CONTACTED BY MAILING |
| 06/29/2017 | NOTICE OF VIOLATION ISSUED |
| 07/03/2018 | VIOLATION CLOSED |