Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T17DV02735
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2017 | INSP - INITIAL CODE ENFORCMENT | Approved | ONSITE INSPECTION OF BLDG. 8 EXTERIOR INSPECTION OF BUILDING 8, THIS BUILDING IS A 2 STORY BUILDING WITH 4 UNITS. THE BUILDING IS A CMU TYPE BUILDING. . THE FRONT OF THE BUILDING HAS AN OPEN PORCH WITH A STEEL FRAMED STAIRCASE WITH CONCRETE STEPS. THE REAR OF THE BUILDING HAS A WOOD FRAMED REAR CANTILEVER BALCONY WITH DECKING BOARDS AND A METAL RAILING. THIS WAS A VISUAL INSPECTION FROM THE GROUND FLOOR. BELOW ARE THE CODE VIOLATIONS FRONT OF THE BUILDING DECKING BOARDS HAVE DETERIORATED AND ARE DAMAGED DUE TO WOOD ROT. RIM JOIST IS DAMAGED AND THERE'S A SECTION IS MISSING BETWEEN THE STAIRCASE AND DECK. MULTIPLE FLOOR JOISTS HAVE SEVERE WOOD ROT DAMAGE MULTIPLE BEAMS HAVE LOOSE HARDWARE. REAR OF THE BUILDING THE BALCONIES HAVE HEAVY DETERIORATION AND WOOD ROT DAMAGE TO THE DECKING BOARDS, THERE ARE BOARDS WHICH HAVE UPLIFTED DUE TO WRAP AND MISSING FASTENERS. ELECTRICAL JUNCTION BOX HAS MISSING COVER |