Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

10/19/2016

Applicant:

WORTH REALITY ATTN: MELISSA MCCORMICK

Description:

CLOSET LIGHT DOES NOT FUNCTION DILAPTED ROOF IN BED ROOM LEAKING WHEN IT RAINS

Case Violations

Case Number: T16DV07292
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
10/28/2016 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
10/28/2016 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
10/28/2016 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Outstanding Inspections

Case Number: T16DV07292
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
06/05/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VINDIOLA Item closed
06/05/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VINDIOLA Item closed
06/05/2017 NPO(PL)-PLUMBING SYSTEM & FX VINDIOLA Item closed
06/05/2017 NPO - WEEDS/GRASSES VINDIOLA Item closed
10/19/2016 NPO(DL)-DILAPIDATED STRUCTURE FLORES Item initialized
10/19/2016 NPO - OTHER FLORES Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV07292
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/28/2016 INSP - INITIAL CODE ENFORCMENT VINDIOLA Approved Arrived on site and met with tenant, showed me 3 inground lights to landscaping with broken conduit and missing cover plate to junction box in front of unit 32. Electrical Panel has brush and overgrown not allowing for working clearance at rear of complex. Swimming pool has a edge tile loose when you put weight on it (block with 5ft marker on it). One gas dryer with face plate panel missing in front side of machine with now access to flame when dryer is on.
12/06/2016 INSP - FOLLOW UP CODE ENFORCE VINDIOLA Approved Arrived on site, to find weeds and grass along rear of complex by electrical panel still on site. Electrical panel in rear of complex still missing blanks, open to bus bar. Electrical lighting by mailbox and by units 7 and 9 still broken conduit and exposed wiring. Did replace faceplate to unit 32, covered open face in dryer , and secured top tile to swiming pool. Will make contact with Werth Realty for outstanding violations

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T16DV07292
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
10/26/2016 CONTACTED BY PHONE
11/02/2016 CONTACTED BY MAILING
11/01/2016 NOTICE OF VIOLATION ISSUED
06/05/2017 VIOLATION CLOSED

Documents

File Name Document Type  
3455 N COUNTRY CLUB NOV1.PDF DOCUMENTS VIEW
3255 N COUNTRY CLUB NOV1.PDF DOCUMENTS VIEW