Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

10/02/2016

Applicant:

ROBLES BARBARA

Description:

COMMUNICATION CALLED THAT T.F.D ON SITE WITH A HOUSE FIRE ALARM #F162760036

Outstanding Inspections

Case Number: T16DV06790
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
11/07/2016 EMERGENCY CALL OUT VIDAL Follow-up inspection
11/07/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Follow-up inspection
11/07/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Follow-up inspection
11/07/2016 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Follow-up inspection
11/07/2016 NPO(PL)-GAS SUPPLY/CONNECT VIDAL Follow-up inspection
11/07/2016 NPO - SMOKE ALARMS VIDAL Follow-up inspection
11/07/2016 NPO - OTHER VIDAL Follow-up inspection
11/07/2016 NPO - EXT. BUILDING MAINTENANC VIDAL Follow-up inspection
11/07/2016 NPO - WORK WITHOUT PERMIT VIDAL Follow-up inspection
11/07/2016 NPO - INT. BUILDING MAINTENANC VIDAL Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV06790
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/02/2016 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Received call from communication that T.F.D. on site with a house fire. Arrived and the units were checking for hot spots. The fire was in the rear porch where the owner was cooking meat in grease pots. The grease caught fire due to not attended. The fire damaged the wood frame porch and some wood siding to a room on the south side. Some wiring to added lights on the roof part of the porch and outlets on the wall were burned. They were connected to the exterior light fixture. Was trying to leave the power on but the main disconnect has a broken bar on the handle to remove and turn on the power. Placed a city lock and will require an upgrade for the electrical to be turned back on. The gas meter was pinned due to the power being turned off. The interior of the house was OK but has some light smoke damage. The fire was in grease pots and those were place in the yard area. They were on gas burners that were not connected to the house. The owner signed all the paper work and has a place to stay. Placed a "Do Not Enter" on the front window. The owner was cleaning the area and will be leaving soon. Will check in 30 days. RV.
11/07/2016 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The house is vacant and secured. Does have storage containers on the property for the items that were in the house. Does have several lock boxes on the security bars by the front door. The electrical has been turned back on. The rear porch is still up and no work has been done to repair the damaged area from the fire. Will check in in 60 days. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T16DV06790
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/27/2016 CONTACTED IN PERSON
10/07/2016 NOTICE OF VIOLATION ISSUED
03/29/2017 VIOLATION CLOSED

Documents

File Name Document Type  
DSCN1011.JPG DOCUMENTS VIEW
DSCN1012.JPG DOCUMENTS VIEW
DSCN1013.JPG DOCUMENTS VIEW
DSCN1014.JPG DOCUMENTS VIEW
DSCN1015.JPG DOCUMENTS VIEW
DSCN1016.JPG DOCUMENTS VIEW
DSCN1017.JPG DOCUMENTS VIEW
DSCN1018.JPG DOCUMENTS VIEW
DSCN1019.JPG DOCUMENTS VIEW
DSCN1020.JPG DOCUMENTS VIEW
DSCN1021.JPG DOCUMENTS VIEW
DSCN1022.JPG DOCUMENTS VIEW
DSCN1023.JPG DOCUMENTS VIEW
DSCN1024.JPG DOCUMENTS VIEW
DSCN1025.JPG DOCUMENTS VIEW
DSCN1026.JPG DOCUMENTS VIEW
DSCN1027.JPG DOCUMENTS VIEW
DSCN1028.JPG DOCUMENTS VIEW
DSCN1029.JPG DOCUMENTS VIEW
DSCN1030.JPG DOCUMENTS VIEW
DSCN1031.JPG DOCUMENTS VIEW
DSCN1032.JPG DOCUMENTS VIEW
DSCN1033.JPG DOCUMENTS VIEW
DSCN1034.JPG DOCUMENTS VIEW
DSCN1035.JPG DOCUMENTS VIEW
DSCN1036.JPG DOCUMENTS VIEW
DSCN1037.JPG DOCUMENTS VIEW
DSCN1038.JPG DOCUMENTS VIEW
DSCN1039.JPG DOCUMENTS VIEW
DSCN1040.JPG DOCUMENTS VIEW
DSCN1041.JPG DOCUMENTS VIEW
DSCN1042.JPG DOCUMENTS VIEW
DSCN1043.JPG DOCUMENTS VIEW
DSCN1044.JPG DOCUMENTS VIEW
DSCN1045.JPG DOCUMENTS VIEW
DSCN1046.JPG DOCUMENTS VIEW
DSCN1047.JPG DOCUMENTS VIEW
DSCN1048.JPG DOCUMENTS VIEW
DSCN1049.JPG DOCUMENTS VIEW
DSCN1050.JPG DOCUMENTS VIEW
6001 S EUCLID AVE NOV & ORDER.PDF DOCUMENTS VIEW
DAMAGE REPORT.PDF DOCUMENTS VIEW