Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

09/15/2016

Applicant:

GALLARDO MIGUEL ANGEL & ASHLEY BLANCA CP/RS

Description:

ELECTRICAL VIOLATIONS

Case Violations

Case Number: T16DV05593
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
10/05/2016 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T16DV05593
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
12/16/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Extension granted
12/16/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV05593
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/12/2016 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ONSITE INSPECTION OF THE PARK'S ELECTRICAL SERVICE AND EQUIPMENT. THERE IS NO ACCESS TO THE FOLLOWING UNITS 2, 3, 9, 10, 14, 16, 17, 19, 21, 22 AND THE SERVICE LOCATED INSIDE UNIT 3 YARD. UNIT 1 VACANT SPACE NO DISCONNECT MEANS MISSING CLEAN OUT CAP UNIT 2 NO ACCESS UNIT 3 NO ACCESS UNIT 4 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE CONDUIT IS NOT RATED FOR ITS USE THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 5 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 6 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE IS OBSTRUCTED THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 7 30 AMP DISCONNECTING MEANS / WITH BREAKER NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 8 50 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? NO GROUNDING ELECTRODE SYSTEM THERE ARE TWO GRAY NON SHEATHED METELLIC CABLES EXPOSED AND ABOVE GROUND BEING USED AS THE POWER SUPPLY CORD. THESE CABLES IN THE MANNER CONNECTED ARE PRONE TO PHYICAL DAMAGE. THIS IS AN UNAPPROVED WIRING METHODS. THE JUNCTION BOX HAS BEEN MODIFIED FOR THE INSTALL OF A 50 AMP RECEPTACLE. THE J BOX HAS A PVC TYPE PLUG. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 9 NO ACCESS UNIT 10 NO ACCESS UNIT 11 RE INSPECTION REQUIRED UNIT 11 B UNIT 11 C UNIT 12 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 13 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 14 NO ACCESS UNIT 15 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION SERVICE LOCATION FOR UNITS 12 / 17 UF CABLE EXPOSED FROM THE DISCONNECT TO THE EARTH, NOT AN APPROVED WIRING METHOD UNIT 16 NO ACCESS UNIT 17 NO ACCESS UNIT 18 30 AMP DISCONNECTING MEANS / WITH BREAKER NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS UNIT 19 NO ACCESS UNIT 20 IS OK, 200 AMP SERVICE UNIT 21 NO ACCESS UNIT 22 NO ACCESS UNIT 23 50 AMP HARDWIRED NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS SERVICE LOCATION FOR UNITS 23 /24 /25 ALL 50 AMPS UNIT 24 30 AMP RECEPTACLE NO OVERCURERENCT PROTECTION, DISCONNECT IS RATED AT 50 AMPS. POWER SUPPLY CORD IS RATED AT 30 AMPS ( VERIFIY POWER SUPPY CORD AMPERS) NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION BY FENCE UNIT 25 40 AMP RECEPTACLE NO OVERCURERENCT PROTECTION, DISCONNECT IS RATED AT 50 AMPS. POWER SUPPLY CORD IS RATED AT 40 AMPS ( VERIFIY POWER SUPPY CORD AMPERS) NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS
12/16/2016 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT ISSUED T16CM08513, FOLLOW UP INSPECTION DUE 6-13-2017

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T16DV05593
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
09/21/2016 CONTACTED BY PHONE
10/05/2016 CONTACTED IN PERSON
09/21/2016 CONTACTED BY EMAIL

Documents

File Name Document Type  
20160929_075146.JPG DOCUMENTS VIEW
20160929_075202.JPG DOCUMENTS VIEW
20160929_075434.JPG DOCUMENTS VIEW
20160929_075448.JPG DOCUMENTS VIEW
20160929_075628.JPG DOCUMENTS VIEW
20160929_075642.JPG DOCUMENTS VIEW
20160929_075721.JPG DOCUMENTS VIEW
20160929_075725.JPG DOCUMENTS VIEW
20160929_075908.JPG DOCUMENTS VIEW
20160929_075922.JPG DOCUMENTS VIEW
20160929_080431.JPG DOCUMENTS VIEW
20160929_080435.JPG DOCUMENTS VIEW
20160929_080445.JPG DOCUMENTS VIEW
20160929_080459.JPG DOCUMENTS VIEW
20160929_080501.JPG DOCUMENTS VIEW
20160929_080504.JPG DOCUMENTS VIEW
20160929_080512.JPG DOCUMENTS VIEW
20160929_080516.JPG DOCUMENTS VIEW
20160929_080520.JPG DOCUMENTS VIEW
20160929_082107.JPG DOCUMENTS VIEW
20160929_082119.JPG DOCUMENTS VIEW
20160929_082514.JPG DOCUMENTS VIEW
20160929_082527.JPG DOCUMENTS VIEW
20160929_083008.JPG DOCUMENTS VIEW
20160929_083019.JPG DOCUMENTS VIEW
20160929_083124.JPG DOCUMENTS VIEW
20160929_083129.JPG DOCUMENTS VIEW
20160929_083422.JPG DOCUMENTS VIEW
20160929_083425.JPG DOCUMENTS VIEW
20160929_083946.JPG DOCUMENTS VIEW
20160929_083952.JPG DOCUMENTS VIEW
20160929_084213.JPG DOCUMENTS VIEW
20160929_084218.JPG DOCUMENTS VIEW
20160929_085313.JPG DOCUMENTS VIEW
20160929_085323.JPG DOCUMENTS VIEW
20160929_085338.JPG DOCUMENTS VIEW
20160929_085403.JPG DOCUMENTS VIEW
20160929_090329.JPG DOCUMENTS VIEW
20160929_090337.JPG DOCUMENTS VIEW
20160929_090403.JPG DOCUMENTS VIEW
20160929_090409.JPG DOCUMENTS VIEW
20160929_090414.JPG DOCUMENTS VIEW
20160929_091210.JPG DOCUMENTS VIEW
20160929_091218.JPG DOCUMENTS VIEW
20160929_091223.JPG DOCUMENTS VIEW
20160929_091239.JPG DOCUMENTS VIEW
20160929_091610.JPG DOCUMENTS VIEW
20160929_091947.JPG DOCUMENTS VIEW
20160929_091959.JPG DOCUMENTS VIEW
1681 W PRINCE RD.PDF DOCUMENTS VIEW