Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T16DV05593
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2018 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T16CM08513 FOR UNITS 1-27 PLUS LAUNDRY BUILDING. EXTENSIVE NOTES ADDED TO NOV. INSPECTOR SHOULD REVIEW PRIOR TO ARRIVAL (T16DV05593) WAS APPROVED ON 1-19-2018,, CLOSE CASE | |
08/02/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T16CM08513 WAS REOPENED BY BO,, INSPECTIONS ARE CONTINUING.. PERMIT EXPIRES ON 10-18-2018 | |
04/14/2017 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT T16CM08513 UNITS 1-27 PLUS LAUNDRY BUILDING. EXTENSIVE NOTES ADDED TO NOV. INSPECTOR SHOULD REVIEW PRIOR TO ARRIVAL (T16DV05593) WAS FINAL ON 1-19-2017. THE SPACE VIOLATIONS TO THE EQUIPMENT DISCONNECTS WERE NOT ADDRESSED WILL CALL OWNER | |
12/16/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | PERMIT ISSUED T16CM08513, FOLLOW UP INSPECTION DUE 6-13-2017 |
|
10/04/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | COMPLETED ALL INSPECTIONS: SERVICE DISCONNECT FOR UNITS 1/ 11,D THIS SERVICE IS LOCATED IN SPACE 3 1. VERIFY GROUNDING SYSTEM 2. UNUSED OPENING 3. MISSING DEAD FRONT FROM ENCLOSURE 11/D SERVICE DISCONNECT FOR UNITS 12/17 THIS SERVICE IS LOCATED IN SPACE 15. 1. THERE IS A NON-METALLIC SHEATHED CABLE, (UNDERGROUND FEEDER) TYPE: WHICH RUNS FROM THE EARTH TO THE MAIN SERVICE WITH A 4 FOOT PORTION EXPOSED AND UNPROTECTED. IM UNABLE TO READ AMPACITY OF THE FEEDER. 2. UNABLE TO DETERMINE BREAKER AMPACITY FOR THE FOLLOWING MAIN BREAKERS: 12, 15 AND 17. 3. THE FOLLOWING MAIN BREAKERS HAVE MISSING PROTECTIVE COVERS: 13 AND 17. SERVICE DISCONNECT LOCATION FOR UNITS 18,19,21,22, THIS SERVICE IS LOCATED IN SPACE 19 1. MAIN BREAKER LABELED 23 IS AT OTHER LOCATION, UNKNOWN DESIGNATION 2. UNUSED OPENING 3. MAIN BREAKER 21 IS UNREADABLE 4. VERIFY GROUNDING SYSTEM 5. WORKING CLEARANCE IS OBSTRUCTED 6. TWO (2) INCH ELECTRICAL METALLIC TUBING (EMT) HAVE ERODED AT THE POINT THERE THEY MEET THE EARTH 7. (3) ELECTRICAL METALLIC TUBING (EMT) HAVE DETACHED FROM THE BOTTOM OF THE SERVICE DISCONNECT. 8. THERE ARE EXPOSED FEEDERS AT THE BOTTOM OF THE SERVICE DISCONNECT 9. THERE IS GRAY ELECTRICAL CONDUIT WHICH RUNS FROM THE BOTTOM OF THE SERVICE DISCONNECT AND RUNS ALONG THE SURFACE AROUND THE MOBILE HOME, THE CONDUIT IS NOT PROPERLY SECURED AND PRONE TO PHYSICAL DAMAGE. 10. THE WOOD SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. SERVICE DISCONNECT LOCATION FOR UNITS 23 /24 /25 THIS SERVICE IS LOCATED IN SPACE 23 1. INCORRECT GROUNDING ELECTRODE CONDUCTOR SERVICE DISCONNECT FOR UNIT 26 LOCATED IN SPACE 26 1. VERIFY GROUNDING SYSTEM 2. UNUSED OPENING MOBILE HOME AND RV UNITS VIOLATIONS ARE LISTED BELOW UNIT 1 VACANT SPACE NO DISCONNECT MEANS UNIT 2 OVER CURRENT PROTECTION IS A 40 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 40 AMPS MAIN BREAKER, THE POWER SUPPLY CORD AND DISCONNECTING MEANS RECEPTACLE IS RATED FOR 30 AMPS.. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. WORKING CLEARING IS OBSTRUCTED NO GROUNDING ELECTRODE SYSTEM EXPOSED CONDUCTORS AT THE RECEPTACLE RECEPTACLE NOT PROPERLY INSTALLED AND UNSECURED TO THE ENCLOSURE THE RECEPTACLE ENCLOSURE IS NOT PROPERLY SECURED TO THE POST THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 3 OVER CURRENT PROTECTION IS A 30 AMP MAIN BREAKER DISCONNECTING MEANS RECEPTACLE IS 30 AMPS NO GROUNDING ELECTRODE SYSTEM EXPOSED CONDUCTORS WHERE THE POWER SUPPLY CORD MEETS THE CORD CAP. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 4 OVER CURRENT PROTECTION IS A 50 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE POWER SUPPLY CORD AND DISCONNECTING MEANS RECEPTACLE IS RATED FOR 30 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE PVC PIPE IS NOT LISTED FOR ITS USE AS CONDUIT. THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 5 OVER CURRENT PROTECTION IS A 50 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE POWER SUPPLY CORD AND DISCONNECTING MEANS RECEPTACLE IS RATED FOR 30 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 6 OVER CURRENT PROTECTION IS A 30 AMP MAIN BREAKER DISCONNECTING MEANS RECEPTACLE IS 30 AMPS THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE IS OBSTRUCTED THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. DEAD FRONT HAS BEEN MODIFIED FOR ADDITIONAL DUPLEX RECEPTACLE. UNIT 7 OVER CURRENT PROTECTION IS A40 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 40 AMPS MAIN BREAKER, THE DISCONNECTING MEANS BREAKER IS RATED FOR 30 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 8 OVER CURRENT PROTECTION IS A50 AMP MAIN BREAKER DISCONNECTING MEANS RECEPTACLE IS 50 AMPS NO GROUNDING ELECTRODE SYSTEM THERE ARE TWO UNDERGROUND FEEDER TYPE OF CABLES (GRAY NON SHEATHED METALLIC CABLES) EXPOSED AND ABOVE GROUND BEING USED AS THE POWER SUPPLY CORD. THESE CABLES HAVE BEEN INSTALLED IN A MANNER PRONE TO PHYSICAL DAMAGE. THIS IS AN UNAPPROVED WIRING METHODS. THE JUNCTION BOX HAS BEEN MODIFIED FOR THE INSTALL OF A 50 AMP RECEPTACLE. THE J BOX HAS A PVC TYPE PLUG ON THE ENCLOSURE. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 9 OVER CURRENT PROTECTION IS A50 AMP MAIN BREAKER VERIFY DISCONNECTING MEANS FUSE TYPE AND SIZE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 10 OVER CURRENT PROTECTION IS A50 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE DISCONNECTING MEANS IS A FUSE WHICH IS UNREADABLE DAMAGED DUPLEX RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS VERIFY DISCONNECTING MEANS FUSE TYPE AND SIZE UNIT 11 D VACANT SPACE OVER CURRENT PROTECTION IS A50 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE DISCONNECTING MEANS RECEPTACLE IS RATED FOR 30 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. UNUSED OPENING THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM UNIT 11 B VACANT SPACE OVER CURRENT PROTECTION IS A30 AMP MAIN BREAKER MISSING DISCONNECTING MEANS RECEPTACLE EXPOSED UNPROTECTED WIRING INSIDE THE ENCLOSURE THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM UNIT 11 AND 11 C OVER CURRENT PROTECTION IS A50 AMP MAIN BREAKER FOR BOTH 11 AND 11C LAUNDRY ROOM BUILDING NOT IN USED, BOARDED MISSING DEAD FRONTS AND COVERS ON THE ELECTRICAL PANELS EXPOSED WIRING THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM UNIT 12 OVER CURRENT PROTECTION IS UNREADABLE DISCONNECTING MEANS RECEPTACLE IS 50 AMPS NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 13 OVER CURRENT PROTECTION IS A45 AMP MAIN BREAKER DISCONNECTING MEANS RECEPTACLE IS 50 AMPS NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 14 OVER CURRENT PROTECTION IS 40 AMPS THE MAIN BREAKER AT THE SERVICE IS A 40 AMPS MAIN BREAKER, THE DISCONNECTING MEANS RECEPTACLE IS RATED FOR 50 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. MISSING HARDWARE ON THE ENCLOSURE THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 15 OVER CURRENT PROTECTION IS UNREADABLE DISCONNECTING MEANS RECEPTACLE IS RATED AT 50 AMPS NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION UNIT 16 OVER CURRENT PROTECTION IS A 30 AMP MAIN BREAKER THE MAIN BREAKER AT THE SERVICE IS A 30 AMPS MAIN BREAKER, THE DISCONNECTING MEANS RECEPTACLE IS RATED FOR 50 AMPS MISSING DEAD FRONT THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 17 OVER CURRENT PROTECTION IS UNREADABLE DISCONNECTING MEANS RECEPTACLE IS RATED FOR 50 AMPS THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM UNIT 18 OVER CURRENT PROTECTION IS A 30 AMP BREAKER DISCONNECTING MEANS RECEPTACLE IS RATED AT 30 AMPS NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 19 OVER CURRENT PROTECTION IS 50 AMP BREAKER HARDWIRED UNIT 20 200 AMP SERVICE UNIT 21 OVER CURRENT PROTECTION IS UNREADABLE DISCONNECTING MEANS RECEPTACLE IS 30 AMPS NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 22 OVER CURRENT PROTECTION IS 50 DISCONNECTING MEANS RECEPTACLE IS RATED FOR 50 AMPS NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 23 OVER CURRENT PROTECTION IS 50 AMP BREAKER 50 AMP HARDWIRED NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 24 OVER CURRENT PROTECTION IS 50 AMP BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE POWER SUPPLY CORD AND DISCONNECTING MEANS RECEPTACLE IS RATED FOR 30 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION BY FENCE UNIT 25 OVER CURRENT PROTECTION IS 50 AMP BREAKER THE MAIN BREAKER AT THE SERVICE IS A 50 AMPS MAIN BREAKER, THE POWER SUPPLY CORD AND DISCONNECTING MEANS RECEPTACLE IS RATED FOR 40 AMPS. THE OVERCURRENT PROTECTION EXCEEDS THE AMPACITY OF THE CONDUCTORS. NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 26 VACANT SPACE 100 AMP SERVICE UNUSED OPENING VERIFY GROUNDING SYSTEM UNIT 27 VACANT SPACE NO EQUIPMENT |
|
09/21/2016 | INSP - FOLLOW UP CODE ENFORCE | Follow-up inspection | ONSITE INSPECTION OF THE PARKS SERVICES, NO MANAGEMENT ONSITE, NORTH DISCONNECTS LOCATED IN SPACE 3 ARE NOT ACCESSIBLE.. TOOK PHOTOS OF THE PARKS SERVICES |