Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T16DV05593
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2016 | INSP - INITIAL CODE ENFORCMENT | Approved | ONSITE INSPECTION OF THE PARK'S ELECTRICAL SERVICE AND EQUIPMENT. THERE IS NO ACCESS TO THE FOLLOWING UNITS 2, 3, 9, 10, 14, 16, 17, 19, 21, 22 AND THE SERVICE LOCATED INSIDE UNIT 3 YARD. UNIT 1 VACANT SPACE NO DISCONNECT MEANS MISSING CLEAN OUT CAP UNIT 2 NO ACCESS UNIT 3 NO ACCESS UNIT 4 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE CONDUIT IS NOT RATED FOR ITS USE THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 5 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 6 30 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS NO GROUNDING ELECTRODE SYSTEM WORKING CLEARANCE IS OBSTRUCTED THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED. UNIT 7 30 AMP DISCONNECTING MEANS / WITH BREAKER NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 8 50 AMP RECEPTACLE NO ACCESS TO OVER CURRECT PROTECTION DEVICE, MANAGER ONSITE? NO GROUNDING ELECTRODE SYSTEM THERE ARE TWO GRAY NON SHEATHED METELLIC CABLES EXPOSED AND ABOVE GROUND BEING USED AS THE POWER SUPPLY CORD. THESE CABLES IN THE MANNER CONNECTED ARE PRONE TO PHYICAL DAMAGE. THIS IS AN UNAPPROVED WIRING METHODS. THE JUNCTION BOX HAS BEEN MODIFIED FOR THE INSTALL OF A 50 AMP RECEPTACLE. THE J BOX HAS A PVC TYPE PLUG. THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 9 NO ACCESS UNIT 10 NO ACCESS UNIT 11 RE INSPECTION REQUIRED UNIT 11 B UNIT 11 C UNIT 12 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS UNIT 13 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS THE SUPPORT SYSTEM IS UNSTABLE AND NOT PROPERLY SUPPORTED UNIT 14 NO ACCESS UNIT 15 50 AMP RECEPTACLE NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION SERVICE LOCATION FOR UNITS 12 / 17 UF CABLE EXPOSED FROM THE DISCONNECT TO THE EARTH, NOT AN APPROVED WIRING METHOD UNIT 16 NO ACCESS UNIT 17 NO ACCESS UNIT 18 30 AMP DISCONNECTING MEANS / WITH BREAKER NO GROUNDING ELECTRODE SYSTEM UNUSED OPENINGS UNIT 19 NO ACCESS UNIT 20 IS OK, 200 AMP SERVICE UNIT 21 NO ACCESS UNIT 22 NO ACCESS UNIT 23 50 AMP HARDWIRED NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS SERVICE LOCATION FOR UNITS 23 /24 /25 ALL 50 AMPS UNIT 24 30 AMP RECEPTACLE NO OVERCURERENCT PROTECTION, DISCONNECT IS RATED AT 50 AMPS. POWER SUPPLY CORD IS RATED AT 30 AMPS ( VERIFIY POWER SUPPY CORD AMPERS) NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS WORKING CLEARANCE OBSTRUCTION BY FENCE UNIT 25 40 AMP RECEPTACLE NO OVERCURERENCT PROTECTION, DISCONNECT IS RATED AT 50 AMPS. POWER SUPPLY CORD IS RATED AT 40 AMPS ( VERIFIY POWER SUPPY CORD AMPERS) NO GROUNDING ELECTRODE SYSTEM THERE IS NO CIRCUIT DIRECTORY, IDENTIFICATION OR PROPER LABELING ON DISCONNECTING MEANS |