Case: T16DV04841
Case Details
Entered Date:
08/10/2016
Applicant:
GLOVER TRACY P & KIRSTEN JT/RS
Description:
HOUSE FIRE
Case Violations
Case Number: T16DV04841
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 08/11/2016 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 08/11/2016 | T.C. Ch. 16, Sec. 16-12(b)(2) WALLS. Exterior walls shall be maintained in a sound condition that is substantially weathertight and weatherproof, and shall be protected from the elements by paint or other approved protective covering. Exterior walls must be free of loose, crumbling or deteriorated plaster or rotted, split or buckled exterior wall coverings. |
| 08/11/2016 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 08/11/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 08/11/2016 | T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire. |
| 08/18/2016 | NOTICE OF VIOLATION ISSUED |
Outstanding Inspections
Case Number: T16DV04841
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2016 | NPO - WORK WITHOUT PERMIT | VINDIOLA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV04841
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/10/2016 | INSP - INITIAL CODE ENFORCMENT | VINDIOLA | Approved | 08/10/2016 - Compliant: Emergency House Fire: Arrived on site and met with fire captain and then fire inspector. Fire was in rear bedroom ceiling and wall and ceiling in closet in same room. Wire in old conduit was the point of ignition . Two holes cut in roof & ceiling in bedroom and closet by fire deptment, approx. 3x3. Sheet of sheetrock also rip down in wall, again from fire dept. Roof was tarped by FD. Electrical system had a sub panel in closet of 1st bedroom and fuses did not pop. Checked main panel fire dept states they shut all breakers and breaker did not trip during fire. Panel lacks working space dure to washer and dryer in way. Panel lacks main disconnect. First bedroom lacks egress both windows blocked by window A/C units. Extension cords in first bedroom Southwest Gas checked and pined gas meter. |
| 11/07/2016 | INSP - FOLLOW UP CODE ENFORCE | VINDIOLA | Approved | Back on site to find structure vacant still, but moving forward on repairs. Checked permit plus to find a permit was issued for repairs and upgrades from fire on 10/18/2016. Will move to close out this case as PDSD will be doing all inspection from this point on |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T16DV04841
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 10/04/2016 | CONTACTED BY PHONE |
| 08/18/2016 | CONTACTED BY MAILING |
| 11/07/2016 | VIOLATION CLOSED |