Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

02/11/2016

Applicant:

ROMERO LOUIS JR

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A HOUSE FIRE, ALARM # F160400036

Outstanding Inspections

Case Number: T16DV00755
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
04/27/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT GOODMAN Item closed
04/27/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed
04/27/2016 NPO - SMOKE ALARMS GOODMAN Item closed
04/27/2016 NPO - OTHER GOODMAN Item closed
04/27/2016 NPO - EXT. BUILDING MAINTENANC GOODMAN Item closed
04/27/2016 NPO - WORK WITHOUT PERMIT GOODMAN Item closed
04/27/2016 NPO - INT. BUILDING MAINTENANC GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV00755
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 3
End Date Description Inspector Results Comments
02/11/2016 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Communication called that T.F.D. on site with a house fire. Arrived and the fire was in the carport area in the rear of the house. The fire did not enter the main house where the living area is located. There was a wall that separated the carport from the main house. The north wall is a wood frame wall with a 1-coat system on the framing. The stucco has heat damage and will need to be checked. The 2-car carport is a total lost and needs to be demo'ed and replaced with new with a permit. The property has fencing around the property and the gates are locked by the owner. Did have a vehicle in the carport and that burned and also a total lost. The wires for the service were burned in the fire and wires were cut at the pole. The gas meter was pinned due to lacking electrical to the property and will be turned back on once the electrical has been turned back on. Once the electrical is back on, will need to call Southwest Gas to let them know and the gas will be turned back on. The owner will be able to stay in the house and was told that the power will be turned back on and will be sending a crew to install new wiring. The owner signed the paper work. Will check in 60 days. RV.
04/27/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved
04/27/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOLLOW UP INSPECTION FOUND WORK COMPLAETED UNDER PERMIT T16CM01883. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T16DV00755
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
02/12/2016 CONTACTED BY PHONE
02/24/2016 CONTACTED IN PERSON
02/24/2016 NOTICE OF VIOLATION ISSUED
11/14/2016 PERMIT ISSUED - T##XX#####
11/14/2016 VIOLATION CLOSED
03/30/2016 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
02/12/2016 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
PICTURE 2112.JPG DOCUMENTS VIEW
PICTURE 2100.JPG DOCUMENTS VIEW
PICTURE 2101.JPG DOCUMENTS VIEW
PICTURE 2102.JPG DOCUMENTS VIEW
PICTURE 2103.JPG DOCUMENTS VIEW
PICTURE 2104.JPG DOCUMENTS VIEW
PICTURE 2105.JPG DOCUMENTS VIEW
PICTURE 2106.JPG DOCUMENTS VIEW
PICTURE 2107.JPG DOCUMENTS VIEW
PICTURE 2108.JPG DOCUMENTS VIEW
PICTURE 2109.JPG DOCUMENTS VIEW
PICTURE 2110.AVI DOCUMENTS VIEW
PICTURE 2111.JPG DOCUMENTS VIEW
1502 W. SAINT CLAIR ST. DAMAGE REPORTS AND NOVS.PDF DOCUMENTS VIEW