Case: T15DV08762
Case Details
Entered Date:
11/12/2015
Applicant:
ROSENBAUM JOSEPH M & RHONDA M CP/RS
Description:
CAR INTO DETACHED CARPORT
Outstanding Inspections
Case Number: T15DV08762
Case Status: COMPLIAN
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/11/2015 | NPO - WORK WITHOUT PERMIT | CAMACHO | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV08762
Case Description: CAR THROUGH RESIDENTIAL BUILDI
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/11/2015 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, UPON ARRIVAL FOUND A DETACHED CARPORT/ STORAGE AREA AND MEASUREMENTS UNDER ROOF MEASURED 16' X 28', 16' X 22' WAS THE CARPORT, AND 6' X 16 WAS THE STORAGE. STRUCTURE WAS WELL BUILT, PRE 1998. CAR ENTERED THE FRONT (EAST WALL) AT THE DOORWAY AND NEARLY EXITED THE REAR WALL BUT DAMAGING BOTH WALLS. THE ROOF SYSTEM WAS 2 X 4, 24 " O.C. WITH 1X8 T&G SHEATHING, THERE WAS ALSO A 2X6 BOTTOM CORD SPANNING BEAM TO BEAM AND CONNECTED TO THE REAFTERS ON EITHER SIDE. TOP OF RAFTERS{PEAK) NAILED TO 2X6 RIDGE. THE 4X6 BEAM SAT ON TOP OF 4X6 POSTS AND POCKETED INTO THE STORAGE WALLS AT THE WEST END. SWAY BRACING AND CROSSING BRACING ALL COMPLETED. THE STORAGEROOM WAS ALSO WELL BUILT EXCEPT BOTTOM PLATES WERE 1X4 CUT NAILED TO THE CONCRETE, PROBABLY THE REASON FRONT AND REAR WALL PULLED AWAY FROM THE CONCRETE. A PERMIT IS BEING REQUIRED SO THAT BOTTOM PLATES CAN BE CORRECTED WITH 2X 4 BOLTED TO THE CONCRETE AND SO THAT ALL FASTNERS CAN BE ADDED TO THE CARPORT AREA. (RAFTERS TO BEAM, BEAM TO POST, AND POST TO THE CONCRETE). NOV WAS ISSUED ON SITE AND SIGNED FOR BY TENANT DANIEL GILMORE. |
| 11/13/2015 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | REVISITED SITE, MET WITH OWNER AND CONTRACTOR, WENT OVER NEW DAMAGE TO THE EXISTING STRUCTURE, (PRE 1998) EXPLAINED REPAIRS THAT WOULD BE REQUIRED, ALSO WENT OVER WHAT WOULD BE REQUIRED TO BRING CARPORT UP TO CODE REGARDING THE CONNECTORS, AND WENT OVER PERMITTING ISSUES. |
Completed Activity Special Conditions
Case Description - CAR THROUGH RESIDENTIAL BUILDI
Case Number - T15DV08762
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 11/13/2015 | CONTACTED IN PERSON |
| 11/13/2015 | CONTACTED BY MAILING |
| 11/13/2015 | NOTICE OF VIOLATION ISSUED |
| 11/30/2016 | VIOLATION CLOSED |