Case: T15DV08762

Parcel: 113103610


Addresses:

1447 E SPRING ST

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
01/29/2016 INSP - FOLLOW UP CODE ENFORCE Approved REVISITED SITE, FOUND RAFTER TIES ADDED RAFTER TO BEAM, BEAM TO POST CONNECTORS ADDED, POST TO CONCRETE CONNECTOR (POST BASE) ADDED, AND EXISITING SWAY BRACE AT CORNERS OF THE CARPORT HAD PLYWOOD ADDED FOR EXTRA SHEAR STRENGTH. 2X4 BOTTOM PLATE WAS ADDED TO THE ENTIRE STORAGE AREA CONNECTED TO CONCRETE WITH 1/2" REDHEADS, DAMAGED STUDS REPLACED AND NEW T-III ADDED TO THE EXTERIOR OF STORAGE, WITH CORRECT NAIL OFF PATTERN. COMPLIANCE / CLOSE CASE.
11/13/2015 INSP - FOLLOW UP CODE ENFORCE Approved REVISITED SITE, MET WITH OWNER AND CONTRACTOR, WENT OVER NEW DAMAGE TO THE EXISTING STRUCTURE, (PRE 1998)
EXPLAINED REPAIRS THAT WOULD BE REQUIRED, ALSO WENT OVER WHAT WOULD BE REQUIRED TO BRING CARPORT UP TO CODE REGARDING THE CONNECTORS, AND WENT OVER PERMITTING ISSUES.