| 01/29/2016 | INSP - FOLLOW UP CODE ENFORCE | Approved | REVISITED SITE, FOUND RAFTER TIES ADDED RAFTER TO BEAM, BEAM TO POST CONNECTORS ADDED, POST TO CONCRETE CONNECTOR (POST BASE) ADDED, AND EXISITING SWAY BRACE AT CORNERS OF THE CARPORT HAD PLYWOOD ADDED FOR EXTRA SHEAR STRENGTH. 2X4 BOTTOM PLATE WAS ADDED TO THE ENTIRE STORAGE AREA CONNECTED TO CONCRETE WITH 1/2" REDHEADS, DAMAGED STUDS REPLACED AND NEW T-III ADDED TO THE EXTERIOR OF STORAGE, WITH CORRECT NAIL OFF PATTERN. COMPLIANCE / CLOSE CASE. | |
| 11/13/2015 | INSP - FOLLOW UP CODE ENFORCE | Approved | REVISITED SITE, MET WITH OWNER AND CONTRACTOR, WENT OVER NEW DAMAGE TO THE EXISTING STRUCTURE, (PRE 1998) EXPLAINED REPAIRS THAT WOULD BE REQUIRED, ALSO WENT OVER WHAT WOULD BE REQUIRED TO BRING CARPORT UP TO CODE REGARDING THE CONNECTORS, AND WENT OVER PERMITTING ISSUES. |