Case: T15DV08762

Parcel: 113103610


Addresses:

1447 E SPRING ST

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
11/11/2015 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, UPON ARRIVAL FOUND A DETACHED CARPORT/ STORAGE AREA AND MEASUREMENTS UNDER ROOF MEASURED 16' X 28', 16' X 22' WAS THE CARPORT, AND 6' X 16 WAS THE STORAGE. STRUCTURE WAS WELL BUILT, PRE 1998.
CAR ENTERED THE FRONT (EAST WALL) AT THE DOORWAY AND NEARLY EXITED THE REAR WALL BUT DAMAGING BOTH WALLS. THE ROOF SYSTEM WAS 2 X 4, 24 " O.C. WITH 1X8 T&G SHEATHING, THERE WAS ALSO A 2X6 BOTTOM CORD SPANNING BEAM TO BEAM AND CONNECTED TO THE REAFTERS ON EITHER SIDE. TOP OF RAFTERS{PEAK) NAILED TO 2X6 RIDGE. THE 4X6 BEAM SAT ON TOP OF 4X6 POSTS AND POCKETED INTO THE STORAGE WALLS AT THE WEST END. SWAY BRACING AND CROSSING BRACING ALL COMPLETED.

THE STORAGEROOM WAS ALSO WELL BUILT EXCEPT BOTTOM PLATES WERE 1X4 CUT NAILED TO THE CONCRETE, PROBABLY THE REASON FRONT AND REAR WALL PULLED AWAY FROM THE CONCRETE.
A PERMIT IS BEING REQUIRED SO THAT BOTTOM PLATES CAN BE CORRECTED WITH 2X 4 BOLTED TO THE CONCRETE AND SO THAT ALL FASTNERS CAN BE ADDED TO THE CARPORT AREA. (RAFTERS TO BEAM, BEAM TO POST, AND POST TO THE CONCRETE).
NOV WAS ISSUED ON SITE AND SIGNED FOR BY TENANT DANIEL GILMORE.