Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

11/02/2015

Applicant:

CT PROPERTIES LLC

Description:

T.F.D. ON SITE WITH ELECTRICAL FIRE, ALARM # F153040180

Outstanding Inspections

Case Number: T15DV08438
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
11/03/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Follow-up inspection
11/03/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Follow-up inspection
11/03/2015 NPO - OTHER VIDAL Follow-up inspection
11/03/2015 NPO - WORK WITHOUT PERMIT VIDAL Follow-up inspection
11/03/2015 NPO - INT. BUILDING MAINTENANC VIDAL Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV08438
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/31/2015 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Received call from communication that T.F.D. on site with a electrical fire. Arrived and the unit was still on site and has an electrical J-box that has a short on the interior of the conduit that is PVC. The box has some buring on the cover plate and on the metal box and showing on the drywall. The interior electrical panels for the building have been turned off and still has power going to the box and shorting out in the interior of the box. Are checking other boxes with turning off and still has power. The sound is getting worse and did have the main turn off at the disconnect and all the buildings have no power. A lock out was done on the main switch gear until the contractor shows on site. The maintenance supervisor did call several electrical contractors to check who calls or shows up. JMAC contractor did show and started to work on the finding of the electrical short. He was hired and had help showed to assist. The power was restored to the buildings and has been isolated to the parking lights for the parking lot. All the mechanics shop, auto body and the sales areas all have power at this time. All the parking lights are still off and the sound does not exist any more and everything is working in the other buildings. The building where the J-box is located now has all the power turned back on the no sound in the box of shorting out. The lock out has been removed from the main breaker to the switch gear for the parking light. The contractor or the manager on site will be calling if the wiring can be removed or found where the shorts exist. I will be leaving the site until called. RV.
11/03/2015 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The work has been completed on the repairs. The wiring from the J-box in the building to a light pole in the parking lot has been changed to new. The colors of the wiring were the same that were installed in the same PVC conduit and all is working at this time. All the wiring has been connected that was pulled apart at the J-box and the drywall has been repaired. No permit is required due to no changes made on the conduit and used the same J-box. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T15DV08438
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
07/19/2016 VIOLATION CLOSED

Documents

File Name Document Type  
PICTURE 1845.JPG DOCUMENTS VIEW
PICTURE 1824.JPG DOCUMENTS VIEW
PICTURE 1825.JPG DOCUMENTS VIEW
PICTURE 1826.JPG DOCUMENTS VIEW
PICTURE 1827.JPG DOCUMENTS VIEW
PICTURE 1828.JPG DOCUMENTS VIEW
PICTURE 1829.JPG DOCUMENTS VIEW
PICTURE 1830.JPG DOCUMENTS VIEW
PICTURE 1831.JPG DOCUMENTS VIEW
PICTURE 1832.JPG DOCUMENTS VIEW
PICTURE 1833.JPG DOCUMENTS VIEW
PICTURE 1834.JPG DOCUMENTS VIEW
PICTURE 1835.JPG DOCUMENTS VIEW
PICTURE 1836.JPG DOCUMENTS VIEW
PICTURE 1837.JPG DOCUMENTS VIEW
PICTURE 1838.JPG DOCUMENTS VIEW
PICTURE 1839.JPG DOCUMENTS VIEW
PICTURE 1840.JPG DOCUMENTS VIEW
PICTURE 1841.JPG DOCUMENTS VIEW
PICTURE 1842.JPG DOCUMENTS VIEW
PICTURE 1843.JPG DOCUMENTS VIEW
PICTURE 1844.JPG DOCUMENTS VIEW