Case: T15DV05625
Case Details
Entered Date:
07/30/2015
Applicant:
PLANT MANAGER JIM RICHARDS
Description:
ROOF COLLASPED IN THE LOBBY AREA AND COMMUNICATION CALLED THAT T.F.D. ON SITE
Outstanding Inspections
Case Number: T15DV05625
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 13
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2015 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(PL)-PLUMBING SYSTEM & FX | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(PL)-GAS SUPPLY/CONNECT | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(PL)-WATER HEATERS | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(HC)-COOLING | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(HC)-HEATING & VENTILATION | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO(DL)-DILAPIDATED STRUCTURE | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO - EGRESS | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO - OTHER | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO - EXT. BUILDING MAINTENANC | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO - WORK WITHOUT PERMIT | VALDEZ | Follow-up inspection | |
10/01/2015 | NPO - INT. BUILDING MAINTENANC | VALDEZ | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV05625
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/28/2015 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | THE DAMAGE TO THE BUILDING WAS THE ROOF ASSEMBLY COLLAPSED IN THE LOBBY AREA OF THE MAIN ENTRANCE THE ESTIMATED SQUARE FOOTAGE IS ROUGHLY 30 BY 30. DUE TO THE ROOF COLLAPSING CAUSE DAMAGE TO THE SPRINKLER LINE WHICH IN TURN ENDED UP FLOODING THE ENTIRE BUILDING THE ABUTTING AREAS ALSO HAD A CEILING DAMAGE AND ELECTRICAL DAMAGE AS FAR AS EMT RUNS THAT HAVE BEEN DETACHED AND CRUSHED NOT TO MENTION THE LOBBY AREA AS ELECTRICAL, I INSPECT ENTIRE BUILDING AND THE ROOF, THE FLOORING HAS AN EXCESS WATER OF 3 INCHES TO 4 INCHES IN SOME AREAS. I WALKED OVER TO THE REAR OF THE BUILDING, OUTSIDE IN A LOCK CAGE ARE THE MAIN DISCONNECTS, 6 DISCONNECTS ARE OFF THE ENTIRE BUILDING HAS NO POWER AT THIS TIME.. DC RESTORATION IS ON SITE EXTRACTING WATER FROM THE WAREHOUSE THE BUILDING HAS BEEN CONDEMNED, THE BUILDING CAN BE SECURED BY ITS OWN OPENINGS THERE'S NO DAMAGE TO THE OPENINGS IN THE LOBBY AREA THE BUILDING IS IN CONTROL OF, PLANT MANAGER, DC CONTRACTORS WILL BE THE ONES THAT WILL BE SURVEYING THE DAMAGED AREA IN THE MORNING. THE PLAN OF ACTION IS AS FOLLOW DC PLANS TO BRING A CRANE OVER TO REMOVE THE AC UNIT FROM THE ROOF AREA, DUE TO THE UNIT BEING IN CLOSE PROXIMITY TO THE COLLAPSED AREA. THEY WILL SURVEY THE ENTIRE AREA THAT WAS DAMAGE AND CONTINUE WITH THE WATER EXTRACTION. THE FIRE INSPECTOR SPOKE WITH PLANT MANAGER AND THEY HAVE SCHEDULED A FIRE WATCH, THE COMPANY ALSO HAS A SECURITY COMPANY ON SITE. |
10/01/2015 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | LOBBY TI APPROVED 8-27-2015 T15CM05978 PERMIT T15CM05207:INTERIOR DEMO-FIELD VERIFY THAT ALL LIFE SAFETY ITEMS HAVE BEEN ADDRESSED PERMIT EXPIRES 01/30/2016 PERMIT T15CM05854 FOR 2 MOBILE OFFICES FOR SITE 08/31/2015 FINAL PERMIT T15CM05855 ROOF REPAIR TO EXIST BUILDING EXPIRES 03/26/2016 ALL REPAIRS ARE IAW PERMIT SCHEDULE. FOLLOW UP INSPECTION SET FOR 3-26-2016 |
Completed Activity Special Conditions
Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T15DV05625
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date | Name |
08/11/2015 | CONTACTED BY PHONE |
07/30/2015 | CONTACTED IN PERSON |
08/03/2015 | CONTACTED BY EMAIL |
07/30/2015 | NOTICE AND ORDER ISSUED |
07/30/2015 | NOTICE OF VIOLATION ISSUED |
02/16/2016 | VIOLATION CLOSED |
07/30/2015 | CALLBACK |