Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

07/30/2015

Applicant:

PLANT MANAGER JIM RICHARDS

Description:

ROOF COLLASPED IN THE LOBBY AREA AND COMMUNICATION CALLED THAT T.F.D. ON SITE

Outstanding Inspections

Case Number: T15DV05625
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 13
End Date Description Inspector Results Comments
10/01/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Follow-up inspection
10/01/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Follow-up inspection
10/01/2015 NPO(PL)-PLUMBING SYSTEM & FX VALDEZ Follow-up inspection
10/01/2015 NPO(PL)-GAS SUPPLY/CONNECT VALDEZ Follow-up inspection
10/01/2015 NPO(PL)-WATER HEATERS VALDEZ Follow-up inspection
10/01/2015 NPO(HC)-COOLING VALDEZ Follow-up inspection
10/01/2015 NPO(HC)-HEATING & VENTILATION VALDEZ Follow-up inspection
10/01/2015 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Follow-up inspection
10/01/2015 NPO - EGRESS VALDEZ Follow-up inspection
10/01/2015 NPO - OTHER VALDEZ Follow-up inspection
10/01/2015 NPO - EXT. BUILDING MAINTENANC VALDEZ Follow-up inspection
10/01/2015 NPO - WORK WITHOUT PERMIT VALDEZ Follow-up inspection
10/01/2015 NPO - INT. BUILDING MAINTENANC VALDEZ Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV05625
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/28/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THE DAMAGE TO THE BUILDING WAS THE ROOF ASSEMBLY COLLAPSED IN THE LOBBY AREA OF THE MAIN ENTRANCE THE ESTIMATED SQUARE FOOTAGE IS ROUGHLY 30 BY 30. DUE TO THE ROOF COLLAPSING CAUSE DAMAGE TO THE SPRINKLER LINE WHICH IN TURN ENDED UP FLOODING THE ENTIRE BUILDING THE ABUTTING AREAS ALSO HAD A CEILING DAMAGE AND ELECTRICAL DAMAGE AS FAR AS EMT RUNS THAT HAVE BEEN DETACHED AND CRUSHED NOT TO MENTION THE LOBBY AREA AS ELECTRICAL, I INSPECT ENTIRE BUILDING AND THE ROOF, THE FLOORING HAS AN EXCESS WATER OF 3 INCHES TO 4 INCHES IN SOME AREAS. I WALKED OVER TO THE REAR OF THE BUILDING, OUTSIDE IN A LOCK CAGE ARE THE MAIN DISCONNECTS, 6 DISCONNECTS ARE OFF THE ENTIRE BUILDING HAS NO POWER AT THIS TIME.. DC RESTORATION IS ON SITE EXTRACTING WATER FROM THE WAREHOUSE THE BUILDING HAS BEEN CONDEMNED, THE BUILDING CAN BE SECURED BY ITS OWN OPENINGS THERE'S NO DAMAGE TO THE OPENINGS IN THE LOBBY AREA THE BUILDING IS IN CONTROL OF, PLANT MANAGER, DC CONTRACTORS WILL BE THE ONES THAT WILL BE SURVEYING THE DAMAGED AREA IN THE MORNING. THE PLAN OF ACTION IS AS FOLLOW DC PLANS TO BRING A CRANE OVER TO REMOVE THE AC UNIT FROM THE ROOF AREA, DUE TO THE UNIT BEING IN CLOSE PROXIMITY TO THE COLLAPSED AREA. THEY WILL SURVEY THE ENTIRE AREA THAT WAS DAMAGE AND CONTINUE WITH THE WATER EXTRACTION. THE FIRE INSPECTOR SPOKE WITH PLANT MANAGER AND THEY HAVE SCHEDULED A FIRE WATCH, THE COMPANY ALSO HAS A SECURITY COMPANY ON SITE.
10/01/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved LOBBY TI APPROVED 8-27-2015 T15CM05978 PERMIT T15CM05207:INTERIOR DEMO-FIELD VERIFY THAT ALL LIFE SAFETY ITEMS HAVE BEEN ADDRESSED PERMIT EXPIRES 01/30/2016 PERMIT T15CM05854 FOR 2 MOBILE OFFICES FOR SITE 08/31/2015 FINAL PERMIT T15CM05855 ROOF REPAIR TO EXIST BUILDING EXPIRES 03/26/2016 ALL REPAIRS ARE IAW PERMIT SCHEDULE. FOLLOW UP INSPECTION SET FOR 3-26-2016

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T15DV05625
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
08/11/2015 CONTACTED BY PHONE
07/30/2015 CONTACTED IN PERSON
08/03/2015 CONTACTED BY EMAIL
07/30/2015 NOTICE AND ORDER ISSUED
07/30/2015 NOTICE OF VIOLATION ISSUED
02/16/2016 VIOLATION CLOSED
07/30/2015 CALLBACK

Documents

File Name Document Type  
PICTURE 1210.JPG IMAGES VIEW
PICTURE 1197.JPG IMAGES VIEW
PICTURE 1198.JPG IMAGES VIEW
PICTURE 1199.JPG IMAGES VIEW
PICTURE 1200.JPG IMAGES VIEW
PICTURE 1201.JPG IMAGES VIEW
PICTURE 1202.JPG IMAGES VIEW
PICTURE 1203.JPG IMAGES VIEW
PICTURE 1204.JPG IMAGES VIEW
PICTURE 1205.JPG IMAGES VIEW
PICTURE 1206.JPG IMAGES VIEW
PICTURE 1207.JPG IMAGES VIEW
PICTURE 1208.JPG IMAGES VIEW
PICTURE 1209.JPG IMAGES VIEW
PICTURE 1210.JPG DOCUMENTS VIEW
PICTURE 1197.JPG DOCUMENTS VIEW
PICTURE 1198.JPG DOCUMENTS VIEW
PICTURE 1199.JPG DOCUMENTS VIEW
PICTURE 1200.JPG DOCUMENTS VIEW
PICTURE 1201.JPG DOCUMENTS VIEW
PICTURE 1202.JPG DOCUMENTS VIEW
PICTURE 1203.JPG DOCUMENTS VIEW
PICTURE 1204.JPG DOCUMENTS VIEW
PICTURE 1205.JPG DOCUMENTS VIEW
PICTURE 1206.JPG DOCUMENTS VIEW
PICTURE 1207.JPG DOCUMENTS VIEW
PICTURE 1208.JPG DOCUMENTS VIEW
PICTURE 1209.JPG DOCUMENTS VIEW
5580 S. NOGALES HY DAMAGE REPORT AND NOV.PDF DOCUMENTS VIEW