Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

05/02/2014

Applicant:

BAMHP LLC

Description:

Heating/cooling, electrical issues in 2 bedroom, hole in roof only covered by a tarp( where swamp cooler was). Stove has a gas leak on a burner, currently disconnected.

Case Violations

Case Number: T14DV02785
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date Code Statue
05/05/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
05/05/2014 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
05/05/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
05/05/2014 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
05/05/2014 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
05/05/2014 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.

Outstanding Inspections

Case Number: T14DV02785
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
11/17/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX STEVENS Item closed
11/17/2014 NPO(PL)-PLUMBING SYSTEM & FX STEVENS Item closed
11/17/2014 NPO(PL)-GAS SUPPLY/CONNECT STEVENS Item closed
11/17/2014 NPO(HC)-COOLING STEVENS Item closed
11/17/2014 NPO(HC)-HEATING & VENTILATION STEVENS Item closed
11/17/2014 NPO - INT. BUILDING MAINTENANC STEVENS Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV02785
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/02/2014 INSP - INITIAL CODE ENFORCMENT STEVENS Approved At site, I spoke to tenant and manager. Water leaks from faust at the tub. Water leaks at the front door from the roof. Rubber cover over the roof and swamp cooler opening, water leaks into the trailer at the hallway and back door. The back door is not an exterior door. There is no molding or trim around the the back door. light can be seen between the door jamb and traialer frame. Rear bedroom window frame broken. Living room frame broken. Water heater name plate states 220-240 volts, but power to the heater is being supplied by a 14 gauge wire. Breakers in panel box are all 15 & 20 amp breakers. Panel box not labeled. No cooling system. F/U 30 days.
11/17/2014 INSP - FOLLOW UP CODE ENFORCE STEVENS Approved At site, spoke to owner, all issues abated. Close case.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T14DV02785
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
05/06/2014 CONTACTED BY MAILING
05/06/2014 NOTICE OF VIOLATION ISSUED
11/17/2014 VIOLATION CLOSED

Documents

File Name Document Type  
T14DV02785.PDF DOCUMENTS VIEW