Case: T14DV00336
Case Details
Entered Date:
01/17/2014
Applicant:
1/3 NG NENA & 1/3 YOUNG NOLA 1/3 DANNY F NG TR ATTN: DESERT WILLOW TRAILER PK
Description:
Exterior minimum housing inspection.
Case Violations
Case Number: T14DV00336
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date | Code Statue |
---|---|
01/21/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
01/21/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
01/21/2014 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
01/21/2014 | T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (5) The building, structure, or any portion or member or appurtenance thereof is likely to fail, or to become detached or dislodged, or to partially or completely collapse and thereby injure persons or damage property. |
Outstanding Inspections
Case Number: T14DV00336
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | MENDOZA | Item closed | |
06/10/2014 | NPO(PL)-WATER HEATERS | MENDOZA | Item closed | |
06/10/2014 | NPO(DL)-DILAPIDATED STRUCTURE | MENDOZA | Item closed | |
06/10/2014 | NPO - EXT. BUILDING MAINTENANC | MENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV00336
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2014 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | Water heater lacks exhaust vent, cold water shut off and enclosure. 12/2 romex wire connected to a 100 amp breaker to power a dryer. Splice was taken from one plug pole to power 120v box for the washer and extension cords. All wires exposed and unsecured. Breaker shut off to eliminate hazard. 0 day NOV given for removal of circuit and electrical run. Electrical run removed per Supervior on site. Lifeline is spliced and unprotected on the ground at the bottom of the structure near the washer. Shade structure over the washer and dryer is 2x4 construction and is deteriorated. Also is not contected in one area. Fascia on the south side of the building is extremely deteriorated and lacks paint protection. |
06/10/2014 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | Exterior outlet has cover installed. Vent pipe repaired and at proper height. Dilapidated shade structure at the rear removed. Water heater has gas shut off, TPRV pipe and exhaust vent installed. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV00336
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
01/21/2014 | CONTACTED IN PERSON |
01/21/2014 | NOTICE OF VIOLATION ISSUED |
06/11/2014 | VIOLATION CLOSED |