Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2014 | INSP - FOLLOW UP CODE ENFORCE | Approved | Exterior outlet has cover installed. Vent pipe repaired and at proper height. Dilapidated shade structure at the rear removed. Water heater has gas shut off, TPRV pipe and exhaust vent installed. | |
| 03/18/2014 | INSP - FOLLOW UP CODE ENFORCE | Approved | Sewer vent does not extend past the roof line. 220 dryer outlet missing weather protective cover. Water leak near the meter area. Water heater lacks TPRV drain pipe. Vent not high enough. Missing collar at water heater/exhaust connection. gas shut off not accessible. |
|
| 01/10/2014 | INSP - FOLLOW UP CODE ENFORCE | Approved | 100 amp breaker removed from the panel and blanked off. Lifeline is connected within the structure and a 220 plug mounted outside for the washer. Box is not weather protected and lacks bubble cover. |