Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T14DV00336
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/09/2014 | INSP - INITIAL CODE ENFORCMENT | Approved | Water heater lacks exhaust vent, cold water shut off and enclosure. 12/2 romex wire connected to a 100 amp breaker to power a dryer. Splice was taken from one plug pole to power 120v box for the washer and extension cords. All wires exposed and unsecured. Breaker shut off to eliminate hazard. 0 day NOV given for removal of circuit and electrical run. Electrical run removed per Supervior on site. Lifeline is spliced and unprotected on the ground at the bottom of the structure near the washer. Shade structure over the washer and dryer is 2x4 construction and is deteriorated. Also is not contected in one area. Fascia on the south side of the building is extremely deteriorated and lacks paint protection. |