Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

08/10/2012

Applicant:

UNIVERSITY 4 LP

Description:

Laundry Room - washers and dryers are not wired propertly. Room has trash in it. Water not always on at the park. Water and gas is turned off quite frequently. Weeds and grass overgrown around the park. Sewer system often overfills and flows out into the park. Caller thinks that the lack of weed cutting is causing the possible sewer issues. She said the weeds and vegetation is thick inside the park. Caller was told to call us the next time there is an actual sewer overflow problem.

Outstanding Inspections

Case Number: T12DV06926
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
11/08/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Item closed
11/08/2012 NPO(PL)-WATER HEATERS LPUMPHRE Item closed
11/08/2012 NPO - WEEDS/GRASSES LPUMPHRE Item closed
11/08/2012 NPO - WORK WITHOUT PERMIT LPUMPHRE Item closed
12/18/2012 NPO - REFUSE/TRASH/DEBRIS LPUMPHRE Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV06926
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/20/2012 INSP - INITIAL CODE ENFORCMENT LPUMPHRE Approved In building designated as "laundry": 4 commercial gas dryers venting to west exterior wall together through fascia; none of the terminations have visible dampers; ceiling area is deteriorated in this ceiling area, insulation and ceiling material falling down around venting equipment. No accessible area behind the dryers, unless moved. The area also houses two gas water heaters ventilated separated via the roof; termination missing cap. 4 washers installed on the north wall. None of the outlets are GFCI as required in damp locations. One outlet is not secured to wall and is hanging 2' above washers near wall, despite being in conduit. Floor drain has standing. Additionally, there is accumulation of vegetation over 6" at various locations throughout parcel, as wells as debris, particularly unit 108.
12/18/2012 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved Compliant.

Outstanding Case Activity Conditions

Date Name Approved
08/22/2012 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-11(f) INTERIOR SURFACES AND FEATURES. (5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height. (2) All weeds that exceed 6 inches in height. (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten fee of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. Not Approved
08/22/2012 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T12DV06926
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
10/02/2012 CONTACTED BY PHONE
08/23/2012 CONTACTED BY MAILING
08/30/2012 CERTIFIED RECEIPT CARD
08/21/2012 NOTICE OF VIOLATION ISSUED
12/18/2012 VIOLATION CLOSED