Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T12DV06926
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2012 | INSP - INITIAL CODE ENFORCMENT | Approved | In building designated as "laundry": 4 commercial gas dryers venting to west exterior wall together through fascia; none of the terminations have visible dampers; ceiling area is deteriorated in this ceiling area, insulation and ceiling material falling down around venting equipment. No accessible area behind the dryers, unless moved. The area also houses two gas water heaters ventilated separated via the roof; termination missing cap. 4 washers installed on the north wall. None of the outlets are GFCI as required in damp locations. One outlet is not secured to wall and is hanging 2' above washers near wall, despite being in conduit. Floor drain has standing. Additionally, there is accumulation of vegetation over 6" at various locations throughout parcel, as wells as debris, particularly unit 108. |