Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T12DV06651
Case Details
Entered Date:
08/07/2012
Applicant:
RANCHO DEL MAR APARTMENTS
Description:
HAZARDOUS LANDINGS / STAIRCASES
Case Violations
Case Number: T12DV06651
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
Violation Date | Code Statue |
---|---|
08/07/2012 | CONTACTED BY PHONE |
08/07/2012 | CONTACTED BY EMAIL |
08/07/2012 | T.C. Ch. 16, Sec. 16-14. Dilapidated structures; vacant and unsecured structures; buildings and structures constituting a nuisance. (a) Dilapidated structures. Buildings or structures that are so deteriorated, damaged, dilapidated, or in need of repair so as to present a threat to the health, safety and welfare of the community constitute a nuisance and shall be abated by repair, rehabilitation or demolition as provided in Article VI of this chapter. |
Outstanding Inspections
Case Number: T12DV06651
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/28/2012 | NPO(DL)-DILAPIDATED STRUCTURE | MROMERO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV06651
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2012 | INSP - INITIAL CODE ENFORCMENT | MROMERO | Approved | BUILDING 1 SITE INSPECTION WITH GERALD G. AND RICK S. SHOW POINTS OF ATTACHMENTS' HAS VERTICAL MOVEMENT UP TO AND OVER 1" AND OVER AT STAIRWELL. ANGLE IRON LIP ARE HOLING STAIRS, NO PLACE FOR AGS TO BE USED. IN CASE OF EMERGENCY A LOT OF LATERAL MOVEMENT. ATTEMPTS HAVE BEEN MADE TO PIECE PORTIONS OF LANDINGS TO PREVENT DETONATION OF LANDINGS I.E 2X8 BLOCKS UNDER LANDING AS NAILERS. BUILDING 3 MODIFICATIONS FOR 2ND LEVEL STAIRCASE TO INCLUDE SCABBING WITH IMPROPER LAGS OR THROUGH BOLTS. BUILDING 5 BEAM WELDS AT 2ND LEVEL FOR SUPPORT NOT ANCHORED, POSTS SCABBED TOGETHER TO HELP WITH SUPPORT AND LEFT. BUILDING 13 EXHIBITS SIMILAR CONDITION OF OTHER BUILDING. WITH LANDING DETERIORATED TO POINT OF WOOD 2X6 SCREWS BEING DISLODGED, RAILING SCREWS LODGED TRIP HAZARDS ON WOOD LANDINGS. |
11/28/2012 | INSP - FOLLOW UP CODE ENFORCE | MROMERO | Approved | FU SHOWS WORK COMPLETE, PERMIT T12CM06142 SHOWS BUILDINGS 1,2,3 COMPLETED. FU 30 DAYS FOR 4 THRU 13. CLOSE THIS CASE. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T12DV06651
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
08/09/2012 | CONTACTED BY MAILING |
08/09/2012 | NOTICE OF VIOLATION ISSUED |
12/05/2012 | VIOLATION CLOSED |