Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

03/28/2012

Applicant:

EMPIRE TERRACE LLC 50.0481% & RMA385 PRTNRS LLC 49.9519%

Description:

No gas since Friday, although manager has been working to get it done. Electrical wires exposed in bedroom, no ventilation for water heater.

Case Violations

Case Number: T12DV02443
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 1
Violation Date Code Statue
04/05/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T12DV02443
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
11/13/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Follow-up inspection
11/13/2012 NPO(PL)-GAS SUPPLY/CONNECT JHURD Item closed
11/13/2012 NPO(PL)-WATER HEATERS JHURD Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV02443
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/04/2012 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: MET WITH MANAGER CHARITY, REGIONAL MANAGER KIM, PLUMBING CONTRACTOR SCOTT , (ALL PRO PLUMBING) WENT OVER ISSUES ON UNITS I-52 AND I-49 DUE TO NATURAL GAS LEAKS. 1)-- I-52 HOT WATER TANK INSTALLED BY MAINTENANCE PERSONEL. NO PERMIT ON INSTALLATION. 2)-- INSTALLED INCORRECTLY, BLOCKED OFF ALL COMBUSTION AIR TO HOT WATER TANK AND FORCED AIR HEATER. 3)-- NO EMERGENCY WATER SHUT OFF VALVE. AND/OR NOT ACCESSABLE, NOT VISIBLE. 4)-- TAPED OFF DOUBLE WALL FLUE PIPE THAT GOES THROUGH COMBUSTABLE CHASE. 5)-- INSTALLED TEMPERTURE PRESSURE RELIEF VALVE DRAIN LINE WRONG. STRAIGHT UP THROUGH VENT CHASE TO ROOF. 6)-- DID NOT FOLLOW MANUFACTURES INSTALLATION GUIDE LINES. TO CLOSE TO WALL. 7)-- FLUE PIPE NEEDS MORE PROTECTION, SECURITY TO MAIN FLUE PIPE. OCCUPANT IN PROCESS OF MOVING OUT TO ANOTHER UNIT. UNIT TO BE VACATED TODAY. CONTRACTOR SCOTT: BID WAS TO REPAIR GAS LEAK IN GAS PIPES ONLY NOT TO MAKE REQUIRED CODE & INSTALLATION REPAIRS. IT WAS MENTIONED SOME ONE CAPED OFF THE FLUE PIPE ON THE ROOF. (CHECK). FLUE PIPE ON ROOF OPEN. NO ISSUE. UNIT I-49: WALLS AND CEILING OPENED TO GET TO GAS LINES. I-49 GAS SYSTEM WAS NEVER OPENED FOR ANY REPAIRS ALL REPAIRS DONE TO I-52 GAS LINES. PRESSURE TEST DONE HOLDING FINE, NO LEAKS. 10-10.5 LBS. APPROX 5 DAYS. CONTRACTOR: SECURED PERMIT FOR REPAIRS (GAS LINE) T12PL00263 ISSUED 3/28/2012. CONTRACTOR TO COMPLETE ALL WORK TO HOT WATER TANK INSTALLATION. PASS PERMIT INSPECTION. CONTRACTOR AWARE OF NECESSARY CORRECTIONS. UNIT TO STAY VACANT UNTIL PERMIT FINALED. PER INSPECTOR AND KIM REGIONAL MANAGER. ISSUE 2 A/C UNITS SCATTERED ABOUT COMPLETE COMPLEX DIFFERENT BUILDINGS DIFFERENT UNITS. ALL NEW AND OLD UNIT LACK PROTECTIVE COVERS OPEN EXPOSED TO EXTERIOR ELEMENTS. (240) VOLTS. ELECTRICAL SERVICE EMERGENCY DISCONNECT BOXES ALL OPEN, DETERIORATED, RUSTED. OPEN EXPOSED ELECTRICAL WIRING LAYING ON ROOF TOP. DETERIORATED, CRACKING FROM EXTERIOR ELEMENTS. RESEARCH: A/C PERMITS. N/O/V TO FOLLOW UP.
11/13/2012 INSP - FOLLOW UP CODE ENFORCE JHURD Approved RESEARCH: P.P. SHOWS SEVERAL PERMITS HAVE BEEN EXTENDED TO 4/29/2013. T12CM02434---T12CM02433---T12CM02432---T12CM02431---T12CM02430---T12CM02428---T12CM02430---T12CM02431---T12CM02432---T12CM02433---T12CM02434---T12CM02428-- PERMIT T12CM02426 EXPIRES 1/14/2013 PERMITS:T12CM02429---T12CM02425 FINALED, COMPLIANT. FOLLOW UP 1/15/2013

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T12DV02443
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
04/12/2012 CONTACTED BY PHONE
04/12/2012 CONTACTED IN PERSON
06/13/2012 NOTICE OF VIOLATION ISSUED
07/01/2013 VIOLATION CLOSED
05/11/2012 RESEARCH

Documents

File Name Document Type  
DSC03828.JPG IMAGES VIEW
DSC03829.JPG IMAGES VIEW
DSC03830.JPG IMAGES VIEW
DSC03831.JPG IMAGES VIEW
DSC03832.JPG IMAGES VIEW
DSC03833.JPG IMAGES VIEW
DSC03834.JPG IMAGES VIEW
DSC03835.JPG IMAGES VIEW
DSC03836.JPG IMAGES VIEW
DSC03837.JPG IMAGES VIEW
DSC03838.JPG IMAGES VIEW
DSC03839.JPG IMAGES VIEW
DSC03840.JPG IMAGES VIEW
DSC03841.JPG IMAGES VIEW
DSC03842.JPG IMAGES VIEW
DSC03843.JPG IMAGES VIEW
DSC03844.JPG IMAGES VIEW
DSC03845.JPG IMAGES VIEW
DSC03846.JPG IMAGES VIEW
DSC03847.JPG IMAGES VIEW
DSC03848.JPG IMAGES VIEW
DSC03849.JPG IMAGES VIEW
DSC03850.JPG IMAGES VIEW
DSC03851.JPG IMAGES VIEW
DSC03852.JPG IMAGES VIEW
DSC03853.JPG IMAGES VIEW
DSC03854.JPG IMAGES VIEW
DSC03855.JPG IMAGES VIEW
DSC03856.JPG IMAGES VIEW
DSC03857.JPG IMAGES VIEW
DSC03858.JPG IMAGES VIEW
DSC03859.JPG IMAGES VIEW