Case: T12DV02443
Case Details
Entered Date:
03/28/2012
Applicant:
EMPIRE TERRACE LLC 50.0481% & RMA385 PRTNRS LLC 49.9519%
Description:
No gas since Friday, although manager has been working to get it done. Electrical wires exposed in bedroom, no ventilation for water heater.
Case Violations
Case Number: T12DV02443
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 1
Violation Date | Code Statue |
---|---|
04/05/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T12DV02443
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Follow-up inspection | |
11/13/2012 | NPO(PL)-GAS SUPPLY/CONNECT | JHURD | Item closed | |
11/13/2012 | NPO(PL)-WATER HEATERS | JHURD | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV02443
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/04/2012 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: MET WITH MANAGER CHARITY, REGIONAL MANAGER KIM, PLUMBING CONTRACTOR SCOTT , (ALL PRO PLUMBING) WENT OVER ISSUES ON UNITS I-52 AND I-49 DUE TO NATURAL GAS LEAKS. 1)-- I-52 HOT WATER TANK INSTALLED BY MAINTENANCE PERSONEL. NO PERMIT ON INSTALLATION. 2)-- INSTALLED INCORRECTLY, BLOCKED OFF ALL COMBUSTION AIR TO HOT WATER TANK AND FORCED AIR HEATER. 3)-- NO EMERGENCY WATER SHUT OFF VALVE. AND/OR NOT ACCESSABLE, NOT VISIBLE. 4)-- TAPED OFF DOUBLE WALL FLUE PIPE THAT GOES THROUGH COMBUSTABLE CHASE. 5)-- INSTALLED TEMPERTURE PRESSURE RELIEF VALVE DRAIN LINE WRONG. STRAIGHT UP THROUGH VENT CHASE TO ROOF. 6)-- DID NOT FOLLOW MANUFACTURES INSTALLATION GUIDE LINES. TO CLOSE TO WALL. 7)-- FLUE PIPE NEEDS MORE PROTECTION, SECURITY TO MAIN FLUE PIPE. OCCUPANT IN PROCESS OF MOVING OUT TO ANOTHER UNIT. UNIT TO BE VACATED TODAY. CONTRACTOR SCOTT: BID WAS TO REPAIR GAS LEAK IN GAS PIPES ONLY NOT TO MAKE REQUIRED CODE & INSTALLATION REPAIRS. IT WAS MENTIONED SOME ONE CAPED OFF THE FLUE PIPE ON THE ROOF. (CHECK). FLUE PIPE ON ROOF OPEN. NO ISSUE. UNIT I-49: WALLS AND CEILING OPENED TO GET TO GAS LINES. I-49 GAS SYSTEM WAS NEVER OPENED FOR ANY REPAIRS ALL REPAIRS DONE TO I-52 GAS LINES. PRESSURE TEST DONE HOLDING FINE, NO LEAKS. 10-10.5 LBS. APPROX 5 DAYS. CONTRACTOR: SECURED PERMIT FOR REPAIRS (GAS LINE) T12PL00263 ISSUED 3/28/2012. CONTRACTOR TO COMPLETE ALL WORK TO HOT WATER TANK INSTALLATION. PASS PERMIT INSPECTION. CONTRACTOR AWARE OF NECESSARY CORRECTIONS. UNIT TO STAY VACANT UNTIL PERMIT FINALED. PER INSPECTOR AND KIM REGIONAL MANAGER. ISSUE 2 A/C UNITS SCATTERED ABOUT COMPLETE COMPLEX DIFFERENT BUILDINGS DIFFERENT UNITS. ALL NEW AND OLD UNIT LACK PROTECTIVE COVERS OPEN EXPOSED TO EXTERIOR ELEMENTS. (240) VOLTS. ELECTRICAL SERVICE EMERGENCY DISCONNECT BOXES ALL OPEN, DETERIORATED, RUSTED. OPEN EXPOSED ELECTRICAL WIRING LAYING ON ROOF TOP. DETERIORATED, CRACKING FROM EXTERIOR ELEMENTS. RESEARCH: A/C PERMITS. N/O/V TO FOLLOW UP. |
11/13/2012 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | RESEARCH: P.P. SHOWS SEVERAL PERMITS HAVE BEEN EXTENDED TO 4/29/2013. T12CM02434---T12CM02433---T12CM02432---T12CM02431---T12CM02430---T12CM02428---T12CM02430---T12CM02431---T12CM02432---T12CM02433---T12CM02434---T12CM02428-- PERMIT T12CM02426 EXPIRES 1/14/2013 PERMITS:T12CM02429---T12CM02425 FINALED, COMPLIANT. FOLLOW UP 1/15/2013 |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T12DV02443
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
04/12/2012 | CONTACTED BY PHONE |
04/12/2012 | CONTACTED IN PERSON |
06/13/2012 | NOTICE OF VIOLATION ISSUED |
07/01/2013 | VIOLATION CLOSED |
05/11/2012 | RESEARCH |