Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/05/2011

Applicant:

ANN M. BOYCE 64% & AJDAR VENTUR LLC 17.5% & GILBERT BOYCE 17.5% & MICHAEL RUELAS

Description:

Minimum housing concerns inside unit.

Case Violations

Case Number: T11DV09780
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
12/09/2011 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
12/09/2011 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
12/09/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
12/09/2011 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
12/09/2011 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.

Outstanding Inspections

Case Number: T11DV09780
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
12/09/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Notice of violation
12/09/2011 NPO(HC)-HEATING & VENTILATION HLOPEZ Notice of violation
12/09/2011 NPO - SMOKE ALARMS HLOPEZ Notice of violation
12/09/2011 NPO - EXT. BUILDING MAINTENANC HLOPEZ Notice of violation
12/09/2011 NPO - INT. BUILDING MAINTENANC HLOPEZ Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV09780
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/09/2011 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT Site inspection, present at inspection, tenant, inspector H.Lopez & supervisor R. Saldate. Reviewed issues, (1) Mold in bathroom, informed tenant department does not identify nor address mold issues, tenant must have hygienist identify if it is actually mold & or mildew,(2) Base board heater in bedroom not working correctly, control dial can be forced passed stop. (3) Infestation of bed bugs & roaches, All sheets & covers removed from beds and all seams checked for bed bugs, none present, 2 dead roaches found under sink, no roach dropping present along sinks back splashes, walls in kitchen, however large amounts of grease on stove, burner trays, oven & broiler section. Informed tenant listed conditions are a strong attractant to roaches & should be eliminated as soon as possible. (3) Broken floor tiles, approximately 7 to 8 floors tiles were found broken & or curling up through out 3 bedroom apartment. (4) Possible fire concerns, entry door to bedroom to close to base board heater, Explained base board heaters do not put out enough heat to ignite doors.(5) working smoke detectors missing through out apartment. Stated smoke detector were not present when tenant took apt. Other issue present, hazardous electrical. tenant using unapproved appliance cord to reach electronic ignition stove original power cord.
03/23/2012 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved COMPLIANCE See research entry in condition screen dated 3/23/12 4 details T12CM00923 Electric final approved 3/8/12, permit finaled & TEP clearance approved 3/9/12, remaining violation abated to code requirements.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV09780
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
12/12/2011 CONTACTED BY MAILING
12/09/2011 NOTICE OF VIOLATION ISSUED
03/23/2012 VIOLATION CLOSED
03/23/2012 RESEARCH

Documents

File Name Document Type  
None DOCUMENTS VIEW
T11DV09780.PDF DOCUMENTS VIEW