Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

01/19/2010

Applicant:

WEST MAIN GATE CENTER LLC

Description:

FULL FIRE INSPECTION

Outstanding Inspections

Case Number: T10FR00099
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
VIOL - BUILDING SVCS & SYSTEMS None Not Inspected
01/19/2010 VIOL - FIRE PROTECTION SYSTEMS WMOTTO Correction Required 901.4 Installation. Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered, or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. 1___ NEED TO DROP SPRINKLER HEADS BELOW PALM CANOPY OVER OUTSIDE PATIO BAR UPSTAIRS. 2___ NEED TO HAVE SPRINKLER HEAD IN ROOM OVER MIXER. 3___ NEED SPRINKLER HEAD IN TOOL ROOM.
01/19/2010 VIOL - FIRE PROTECTION SYSTEMS WMOTTO Correction Required 904.1 General. Automatic fire-extinguishing systems, other than automatic sprinkler systems, shall be designed, installed, inspected, tested and maintained in accordance with the provisions of this section and the applicable referenced standards. 1___ NEED TO HAVE KITCHEN HOOD SERVICED AND TAGGED.
01/19/2010 VIOL - FIRE PROTECTION SYSTEMS WMOTTO Correction Required 906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. 1___ CLASS K EXTINGUISHER IN KITCHEN NEEDS TO BE SERVICED.
01/19/2010 VIOL - COMPRESSED GASES WMOTTO Correction Required 3003.5 Security. Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgement and against access by unauthorized personnel in accordance with Sections 3003.5.1 through 3003.5.3. 1___ PROPERLY SECURE GAS CYLINDERS NEAR RISER.

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR00099
Case Description: INSPECTION
Total Completed Inspections - 3
End Date Description Inspector Results Comments
08/31/2010 VIOL - MEANS OF EGRESS WMOTTO Approved ALL VIOLATIONS ABATED
08/31/2010 VIOL - FIRE RESIST.RATED CONST WMOTTO Approved ALL VIOLATIONS ABATED
08/31/2010 INSP - FULL WMOTTO Approved ALL VIOLATIONS ABATED.