Case: T10FR00099

Parcel: 11504602D


Addresses:

865 E UNIVERSITY BL


Inspection Status: Approved

Inspection History: VIOL - FIRE RESIST.RATED CONST

Case Number - T10FR00099

Inspection Description - VIOL - FIRE RESIST.RATED CONST

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2010 VIOL - FIRE RESIST.RATED CONST Approved ALL VIOLATIONS ABATED
01/19/2010 VIOL - FIRE RESIST.RATED CONST Correction Required 703.1 Maintenance. The required fire-resistance rating of
fire-resistance-rated construction (including walls, firestops,
shaft enclosures, partitions, smoke barriers, floors, fire-resistive
coatings and sprayed fire-resistant materials applied to
structural members and fire-resistant joint systems) shall be
maintained. Such elements shall be properly repaired, restored
or replaced when damaged, altered, breached or penetrated.
Openings made therein for the passage of pipes, electrical conduit,
wires, ducts, air transfer openings and holes made for any
reason shall be protected with approved methods capable of
resisting the passage of smoke and fire.

1___ CEILING IN KITCHEN SOUTH WALL NEEDS TO HAVE OPENING CLOSED.
01/19/2010 VIOL - FIRE RESIST.RATED CONST Correction Required 803.4 Fire-retardant coatings. The required flame spread or
smoke-developed index of surfaces in existing buildings shall
be allowed to be achieved by application of approved fire-retardant
coatings, paints or solutions to surfaces having a flame
spread index exceeding that allowed. Such applications shall
comply with NFPA 703 and the required fire-retardant properties
shall be maintained or renewed in accordance with the
manufacturer’s instructions.

1___ PALM COVERINGS OVER UPSTAIRS PATIO BAR NEED TO BE TREATED WITH A FIRE RETARDENT.