Case: T10FR00099

Parcel: 11504602D


Addresses:

865 E UNIVERSITY BL


Inspection Status: Approved

Inspection History: VIOL - MEANS OF EGRESS

Case Number - T10FR00099

Inspection Description - VIOL - MEANS OF EGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2010 VIOL - MEANS OF EGRESS Approved ALL VIOLATIONS ABATED
01/19/2010 VIOL - MEANS OF EGRESS Correction Required 1008.1.8.1 Hardware. Door handles, pulls, latches,
locks and other operating devices on doors required to be
accessible by Chapter 11 of the International Building
Code shall not require tight grasping, tight pinching or
twisting of the wrist to operate.

1___ PANIC HARWARE ON DOOR NEEDS TO BE REPAIRED AT EAST REAR EXIT OF KITCHEN.
2___ UPSTAIRS PATIO EXIT DOOR WITH PANIC HARDWARE REMOVE THUMB TURN LOCK.
01/19/2010 VIOL - MEANS OF EGRESS Correction Required 1028.4 Exit signs. Exit signs shall be installed and maintained in accordance with Section 1011. Decorations, furnishings, equipment or adjacent signage that impairs the visibility of exit signs, creates confusion or prevents identification of the exit shall not be allowed.

1___ EXIT LIGHT OVER BATHROOM NEEDS TO BE REPAIRED.
2___ EXIT SIGN OVER OUTSIDE STAIRS NEEDS TO BE ILLUMINATED. BRUSH NEEDS TO BE TRIMED AWAY.