Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T09DV03692
Case Details
Entered Date:
06/29/2009
Applicant:
MARISCAL CARLOS ARAUJO
Description:
RESIDENTIAL FIRE/ALARM #09391719. TFD ON SITE, ETA REQUESTED
Outstanding Inspections
Case Number: T09DV03692
Case Status: COURTCMP
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 8
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/03/2010 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JVALDEZ | Item closed | |
12/03/2010 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JVALDEZ | Item closed | |
12/03/2010 | NPO(PL)-PLUMBING SYSTEM & FX | JVALDEZ | Item closed | |
12/03/2010 | NPO(PL)-WATER HEATERS | JVALDEZ | Item closed | |
12/03/2010 | NPO(DL)-DILAPIDATED STRUCTURE | JVALDEZ | Item closed | |
12/03/2010 | NPO - REFUSE/TRASH/DEBRIS | JVALDEZ | Item closed | |
12/03/2010 | NPO - JUNKED/INOP. VEHICLE(S) | JVALDEZ | Item closed | |
12/03/2010 | LUC - ZONING OTHER | JVALDEZ | Item closed |
Completed Inspections
Case Status: COURTCMP
Case Number: T09DV03692
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/23/2009 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | SPLIT METERED ELECTRICAL PANEL INSPECTION CONDUCTED ON 6-29-09 RESPONDED TO FIRE CALL DUE TO EXTENSION CORDS ABUSE IN THE INTERIOR. 1. WATER HEATER HAS A CORD FROM THE UNIT TO A RECEPTACLE. 2. CIRCUIT BREAKERS WERE INSTALLED WITH UNDER SIZED CONDUCTORS. 3. CONTRACTOR BERT'S ELECTRICAL MADE CORRECTIONS TO THE WATER HEATER CONNECTION AND THE CIRCUIT BREAKERS 4. FURTHER EDUCATION WAS GIVEN TO OWNER BY ELECTRICIAN ON EXTENSION CORDS AND POWER STRIPS ABUSE. EXTENSION CORDS WERE DISCONNECTED. SPLIT METERED ELECTRICAL PANEL HAS MAIN BREAKER OF 100 AMPS 1. THE ATTACHMENT POINT SERVICE ENTRANCE TO METER CONDUCTORS SIZES ARE NUMBER 6 OR 8. 2. INSTALL OF METAL CONDUIT SIDE OF PANEL BOARD TO EXTERIOR NOT WEATHER TYPE CONNECTORS 3. QUESTIONABLE WIRING METHODS IN RACEWAYS. 4. EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES CEILING AREA. ELECTRICAL CONTRACTOR BERT'S REPORTS AND PROPOSAL RECOMMENDS SERVICE UPGRADE. REVIEWING ALL DATA AND INSPECTION NOTES OF THE SERVICE EQUIPMENT, WIRING METHODS ALONG THE TAMPERING OF CIRCUIT BREAKERS IN A HAZARDOUS MANNER. I DETERMINED A SERVICE UPGRADE IS REQUIRED. THE DWELLING HAS HAD A SERIES OF UNPERMITTED AND UNFINISHED ADDITIONS TO INCLUDE ELECTRICAL. THE AREA IS ESTIMATED AT 664 SQUARE FEET. THE ADDITIONS ARE AS FOLLOWS; ONE BEDROOM HAS HAD ELECTRICAL INSTALLED SUCH AS LIGHTS AND RECEPTACLES. THE BEDROOM HAS UNFINISHED DRYWALL, TWO WINDOW, NO MECHANICAL. THE EXTERIOR WALL OF THE EASTSIDE BEDROOM ADDITION HAS NOT HAD STUCCO FINISH APPLIED. THE UNDERLAYMENT IS EXPOSED, UNPROTECTED. STORAGE ROOM HAS HAD ELECTRICAL INSTALLED SUCH AS LIGHTS, RECEPTACLES, UNFINISHED DRYWALL AND ONE SKYLIGHT. UTILITY ROOM HAS HAD ELECTRICAL INSTALLED SUCH AS LIGHTS, RECEPTACLES, ONE DOOR TO THE EXTERIOR. THIS ROOM CONTAINS A WATER HEATER, EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES IN CEILING. THIS ROOM IS UNFINISHED, NO DRYWALL IN CEILING OR WALLS CLOSET ROOM/ STORAGE HAS EXPOSED NONMETALLIC SHEATHED CABLE UNDER 96 INCHES IN CEILING. THIS ROOM IS UNFINISHED, NO DRYWALL IN CEILING OR WALLS THERE ARE TWO HALLWAYS WITH LIGHTS AND UNFINISHED DRYWALL. ATTACHED, DILAPIDATED PORCH LOCATED NORTH OF THE ADDITIONS. THIS PORCH EXTENT'S OUT TO THE WESTSIDE OF THE ADDITIONS. ROOF AND WOOD MEMBERS ARE FAILING AND DILAPIDATED, NO APPROVED HARE WARE OR CONNECTORS FOR THE STRUCTURAL MEMBERS. EASTSIDE OF THE ADDITION THERE IS A SMALL ATTACHED PORCH, DILAPIDATED, NO APPROVED HARE WARE OR CONNECTORS FOR THE STRUCTURAL MEMBERS NO RECORDS OR APPROVALS FOR ANY BUILDING ADDITIONS AT DEVELOPMENT SERVICE DEPARTMENT CITY OF TUCSON LARGE AMOUNTS OF REFUSE AND DEBRIS ON PROPERTY |
12/08/2009 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | CITY OF TUCSON REQUEST A COURT ORDER TO CONDEMN THE DWELLING AND TERMINATE ALL UTILITIES, DEMOLISH THE REAR AND EASTSIDE DILAPIDATED PORCHES. REMOVE ALL TRASH AND DEBRIS FROM THE PROPERTY. THE DID JUDGE FIND THE DEFENDANT RESPONSIBLE FOR ALL 3 CHARGES AND ORDERED THAT BY JAN 13, 2010 THE DEFENDANT IS TO PROVIDE THE COURT WITH DOCUMENTS FROM A LICENSED CONTRACTOR WHICH STATES THE STRUCTURAL CONDITION OF THE ADDITIONS AND PORCHES ON THE PROPERTY ALSO A PLAN TO ABATE THE VIOLATIONS. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T09DV03692
Case Status: COURTCMP
Total Completed Case Activity Conditions: 11
Date | Name |
08/05/2009 | CONTACTED BY PHONE |
08/05/2009 | CONTACTED IN PERSON |
08/19/2009 | CONTACTED BY MAILING |
06/30/2009 | NOTICE AND ORDER ISSUED |
07/23/2009 | NOTICE OF VIOLATION ISSUED |
10/14/2009 | CITATION ISSUED |
12/03/2010 | VIOLATION CLOSED |
12/08/2009 | COURT HEARING INFO |
07/22/2009 | RESEARCH |
01/20/2010 | REINSPECTION FEE - FIRST |
08/19/2009 | REINSP POSTCARD SENT |