Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

06/06/2007

Applicant:

LANGFAN WILLIAM K TR

Description:

Full Fire Protection Inspection (FPI) conducted 6/4/07

Completed Inspections

Case Status: COMPLETE
Case Number: T07FR01085
Case Description: INSPECTION
Total Completed Inspections - 8
End Date Description Inspector Results Comments
06/13/2007 VIOL - MEANS OF EGRESS DGREENLE Approved TFC 1008.1.8 - Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Padlock on gate outside south dining area. _____ Padlock on gate outside bar. _____ Padlock on gate outside kitchen (above)
06/13/2007 VIOL - MEANS OF EGRESS DGREENLE Approved TFC 1027.2 - Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency. Security devices affecting means of egress shall be subject to approval of the fire code official. _____ Move table near south east door.
06/13/2007 VIOL - MEANS OF EGRESS DGREENLE Approved TFC 1023.6 - Access to a public way. The exit discharge shall provide a direct and unobstructed access to a public way. _____ Egress discharge from kitchen area through gate north of building.
10/29/2007 VIOL - INT.FINISH, DEC. MATL'S BCOBB Approved Flameproof decorations: 807.1 General requirements. In occupancies in Groups A, E, I and R-1 and dormitories in Group R-2, curtains, draperies, hangings and other decorative materials suspended from walls or ceilings shall meet the flame propagation performance criteria of NFPA 701 in accordance with Section 806.2 or be noncombustible. In Groups I-1 and I-2, combustible decorative materials shall meet the flame propagation criteria of NFPA 701 unless the decorative materials, including, but not limited to, photographs and paintings, are of such limited quantities that a hazard of fire development or spread is not present. In Group I-3, combustible decorative materials are prohibited. Fixed or movable walls and partitions, paneling, wall pads and crash pads, applied structurally or for decoration, acoustical correction, surface insulation or other purposes, shall be considered interior finish if they cover 10 percent or more of the wall or of the ceiling area, and shall not be considered decorative materials or furnishings. In Group B and M occupancies, fabric partitions suspended from the ceiling and not supported by the floor shall meet the flame propagation performance criteria in accordance with Section 807.2 and NFPA 701 or shall be noncombustible. ______ Treat the wall decorations and door opening blanket, (if needed), so they are noncombustable, and prove by documentation in either event. Re-inspection date scheduled on or after Nov. 15, 2007. If you have any questions or concerns please call Inspector Cobb at 791-4502 Thank you, _____________________________________________ Brian Cobb, Inspector, Tucson Fire Department __________________________I have received a copy of this inspection report. Building Representative _____________________________________________ Captain
10/29/2007 INSP - FULL BCOBB Approved
11/09/2007 VIOL - FIRE SERVICE FEATURES BCOBB Approved Address done.
11/20/2007 VIOL - BUILDING SVCS & SYSTEMS BCOBB Approved
11/20/2007 INSP - REINSPECTION BCOBB Approved As of 11/20/2007 the cords have been replaced, the rear chain link fence door is scheduled to be done today with panic hardware, and the wall coverings are being removed, and the walls will be painted, as the management was unable to document flameproof quality of fabric. RI in 2 weeks.