Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

05/03/2007

Applicant:

SMITHS FOOD & DRUG CENTERS INC

Description:

Inspection

Outstanding Inspections

Case Number: T07FR00881
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
05/03/2007 INSP - FULL EGRIFFIN Violation 1) Currently no certificate of Occupancy was shown during inspection. I.B.C. 110 certificate of occupancy shall be shown on reinspection. 2) No current records for exhaust system. I.F.C. 904.11.6.3 Shall maintain records on site. Clean hood system and provide records. 3) Excess amount of grease around bench and on floor.I.F.C. 904.11.6.3 Clean floor bench and any accumulation of grease in the area. 4) Jacket and boxes blocking manual activation system for for hood fan.I.F.C. 901.8 Shall remove jacket and boxes from blocking manual activation system. 5) Currently deep frier is not in range of Fire Protection equipment I.F.C. 901.6 Move deep frier under Fire Protection system. 6) Boxes blocking electrical panels. I.F.C. 605.3 No storage of any material shall block electrical panels. 7) Trash compactordoor not self closing. I.F.C. 703.2.2 Automatic door closures shall be maintained and remain in the closed position. 8) Fire extinguishers shall not be obstructed from view. I.F.C. 906.6Fire extinguishers shall be visable and unobstructed, remove all material and boxes from infront of extinguishers. 9) Remove wood from holding damper open. I.F.C.703.1 Repair self closures to electrical room. 10) Boxes stored in hot heater room. 315.2.3 Combustable material shall be removed from hot water room. 11) Boxes are stored on top of coolers without fire protection. 315.2.4Remove boxes from on top of coolers. Remove all items that are combustable from on top of coolers. 12) Extension cord going to T.V. monitor is being used for perminant wiring. I.F.C. 605.5 Extension cords shall not be used for perminant wiring.
06/11/2007 INSP - REINSPECTION JNAGORE Violation On 5-03-07, a fire prevention inspection was conducted at 2001 E. Irvington, Tucson Arizona. On 5-22-07, a re-inspection was conducted and the following International Fire Code 2003 Violation(s) was noted: Enclosed is a copy of your Certificate of Occupancy. Boxes are stored on top of cooler without fire protection. This is in violation of 903.1.1. 903.3.1.1NFPA13 sprinkler systems. Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13 except as provided in Section 903.3.1.1.1. The Tucson Fire code gives you the choice of exempt locations. 903.3.1.1.1 Exempt locations. Automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance rated construction or contains electrical equipment. 1. Any room where the application of water, or flame andwater, constitutes a serious life or fire hazard. 2. Any room or space where sprinklers are considered undesirable because of the nature of the contents, when approved by the fire code official. 3. Generator and transformer rooms separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours. 4. In rooms or areas that are of noncombustible construction with wholly noncombustible contents. Boxes stored on cooler shall be removed or area shall be installed with fire sprinkler system.

Completed Inspections

Case Status: COMPLETE
Case Number: T07FR00881
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
07/26/2007 COMPLIANCE JNAGORE Approved