Case: T06FR02876
Case Details
Entered Date:
12/13/2006
Applicant:
TENNEN DENA V & TENNEN LESLIE I &
Description:
inspection
Outstanding Inspections
Case Number: T06FR02876
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
COMPLIANCE | None | Not Inspected |
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR02876
Case Description: INSPECTION
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/13/2006 | INSP - FULL | EGRIFFIN | Approved | 1). Currently a double sided deadbolt type lock is on front door. This lock is in violation of IFC 1008.1.8, which states: 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. Approved locking device shall be installed. 2). Currently there is a shed, in which the combustible side is within 10 feet an exit. This shed shall be inspected. Arrangements have been made to inspect the contents of this shed. The contents at that time shall be judged to determine the reliability of the exit. IFC 1027.2 1027.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency. Security devices affecting means of egress shall be subject to approval of the fire code official |
12/29/2006 | INSP - REINSPECTION | EGRIFFIN | Approved | On 12-12-0, a fire prevention inspection was conducted at Munchkins Daycare, in Tucson, Arizona. On 12-28-06, a re-inspection was conducted and the following International Fire Code 2003 Violation(s) was noted: Currently there is a shed, in which the combustible side is within 10 feet an exit. This shed shall be inspected. Arrangements have been made to inspect the contents of this shed. The contents at that time shall be judged to determine the reliability of the exit. IFC 1027.2 1027.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency. Security devices affecting means of egress shall be subject to approval of the fire code official The location of the shed is within 10 feet of the rear exit. The contents and structural integrity shall be inspected. This shed could become and impediment to this exit. This letter is to inform you that abatement of these Tucson Fire Code violations must be completed by 1-9-06. An inspection shall occur on 1-9-06. An inspection shall occur on 1-9-06. Under authority of IFC 104.3, which sates 104.3 Right of entry. Whenever it is necessary to make an inspection to enforce the provisions of this code, or whenever the fire code official has reasonable cause to believe that there exists in a building or upon any premises any conditions or violations of this code which make the building or premises unsafe, dangerous or hazardous, the fire code official shall have the authority to enter the building or premises at all reasonable times to inspect or to perform the duties imposed upon the fire code official by this code. If such building or premises is occupied, the fire code official shall present credentials to the occupant and request entry. If such building or premises is unoccupied, the fire code official shall first make a reasonable effort to locate the owner or other person having charge or control of the building or premises and request entry. If entry is refused, the fire code official has recourse to every remedy provided by law to secure entry. |