Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

07/26/2006

Applicant:

ANITA JO S PUTNEYS LLC

Description:

Full Inspection

Outstanding Inspections

Case Number: T06FR02293
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected

Completed Inspections

Case Status: COMPLETE
Case Number: T06FR02293
Case Description: INSPECTION
Total Completed Inspections - 11
End Date Description Inspector Results Comments
07/26/2006 VIOL - FIRE PROTECTION SYSTEMS DRAMIREZ Approved TFC 904.4 Commercial kithen hood system shall be reinspected. You shall provide documention of services rendered and acceptance test results. Shall reinspect the following: 1.) nozzle placement 2.) filters 3.) added appliances
07/26/2006 VIOL - FIRE PROTECTION SYSTEMS DRAMIREZ Approved TFC 901.6 Sprinkler heads in following area shall be inspected; 1.) storage room. 2.) meat cooler.
07/26/2006 VIOL - COMPRESSED GASES DRAMIREZ Approved TFC3003.3 Compressed gas cylinders shall be secured. 1.) in the dry storage room, x 2. 2.) upper level, wet bar, x 2.
07/26/2006 VIOL - FIRE RESIST.RATED CONST DRAMIREZ Approved TFC 703.1 Openings in walls and ceilings: 1.) opening in wall where glass door slides into pocket door enclosure. 2.) dry storage room, ceiling tile 3.) office, ceiling tile. 4.) exterior storage towers, lg. openings. .
07/26/2006 VIOL - BUILDING SVCS & SYSTEMS DRAMIREZ Approved TFC 605.4 Misuse of unapproved multiple adapters in following areas. 1.) in main dining room, under neon sign. 2.) office, under counter. 3.) kitchen, west wall, next to deep vat fryer x 2.
07/26/2006 VIOL - BUILDING SVCS & SYSTEMS DRAMIREZ Approved TFC 605.6 Electrical ,Open junction boxes in the following locations; 1.) conference room, under counter, cover plate. 2.) main office, at enterance and under counter, cover plates. 3.) top side of soffet, open junction boxes. 4.) wall next to fusball table, cover plate. 5.) 2nd. floor next to exit door, open juntion box with exposed wiring.
07/26/2006 VIOL - BUILDING SVCS & SYSTEMS DRAMIREZ Approved TFC 605.5 Misuse of extension / flex cords in the following locations. 1.) dining room area, SW corner, ext. cord. 2.) " , cord extending through wall. 3.) " , cord supplying power to TV sets on tables is extended under floor covering and through wall. 4.) dining area north end, same violation as on # 3 with 5 tables . 5.) conference room, ext. cord to TV set. 6.) dry storage room, cord through ceiling x 2. 7.) kitchen area west wall next to deep vat fryer, ext. cord. 8.) top side of soffet over main bar area,ext. cords.
07/26/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1008.1.9 Panic Hardware: The wrought iron screen door located at the bottom of the stairs leading to the parking lot from the 2nd. floor shall be provided with panic hardware.
07/26/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1008.1.8.3 Signage: A sign shall be posted ajasent to the doors provided with thumb-turn locks that states: " THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED "
07/26/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1008.1.8 Door Operations, All exterior exits shall be provided with a thumb-turn lock with the exception of the main enterance door.
07/26/2006 VIOL - MEANS OF EGRESS DRAMIREZ Approved TFC 1027.2 Exiting / exit access PRE-CITATION: Three required exterior exits are routinly being kept locked.Corrections were made in the presence of the fire offical. Order was given to keep these doors unlocked during business hours . Failure to do so will result with a citation being issued. Exit access in hallway where beer kegs are stored is obstructed by the storage of beer kegs.