Case: T06DV00786
Case Details
Entered Date:
07/05/2006
Applicant:
BOYCE ANN M 30% & AJDAR VENTUR LLC 17.5% & BOYCE
Description:
TUB BACKED UP WEEKS AGO, CARPET WAS DRIED OUT BUT IT SMELLED FOR ABOUT A WEEK. SINK BACKS UP EVERY MORNING WITH A TAR LIKE SUBSTANCE, 5 DAY NOTICE GIVEN FOR NONPAYMENT OF RENT. HAS CALLED HEALTH DEPARTMENT. MANAGEMENT FIXED ONE OF THE ISSUES. DOOR IS NOT CLOSING/OPENING PROPERLY.
Outstanding Inspections
Case Number: T06DV00786
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected | ||
NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
VIOL(EL) - CIRCUITS | None | Not Inspected | ||
NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
VIOL(EL) - FIXTURES | None | Not Inspected | ||
NPO(PL)-SEWAGE DISPOSAL (SYS) | None | Not Inspected | ||
NPO(PL)-WATER HEATERS | None | Not Inspected | ||
VIOL(HC) - OTHER | None | Not Inspected | ||
VIOL(SA) - BATHS | None | Not Inspected | ||
NPO - EGRESS | None | Not Inspected | ||
NPO - SMOKE ALARMS | None | Not Inspected | ||
08/10/2006 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Violation | EXTERIOR INSPECTION FOUND THE MAIN ELCECTRICAL SERVICE PANEL COVER HAD BEEN REMOVED EXPOSING THE MAIN DROP WIRING. MET TENANT AT UNIT. SHE ALLOWED ACCESS INTO THE UNIT. FRONT BEDROOM WINDOW LACKED LOCKING MECHANISM. BATHROOM SINK FILLS WITH WATER/SEWAGE AND DOES NOT DRAIN. LIGHT FIXTURE IN BATHROOM HAS OUTLET THAT IS NOT GROUND PROTECTED. LIGHT LACKS COVER. BATH/TILE JOINTS ARE CRACKED AND NOT PROPERLY SEALED. SMOKE DETECTOR IN THE HALLWAY WAS INOPERABLE. REAR BEDROOM LIGHT LACKS COVER. WINDOW WAS BROKEND AND LACKED LOCKING MECHANISM. SPACE HEATER CONTROL PANEL IN THE LIVING ROOM IS UNSECURED AND HAS EXPOSED ENERGIZED WIRING. LIGHT LACKS COVER. KITCHEN LACKED GFCI PROTECTION. EXHUAST FAN WAS INOPERABLE. WINDOW LACK PROPER LOCKING MECHANISM. WATER HEATER LACKED FRONT PANEL COVER. A/C RETURN VENT IS UNSECURED. UNIT COVERTED FROM A/C TO COOLERS. FRONT DOOR LACKED PROPER WEATHERSTRIPPING. MET WITH PROPERTY MANAGER AND EXPLAINED VIOLATIONS. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T06DV00786
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/03/2006 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | ALL VIOLATIONS ABATED. RM |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T06DV00786
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
08/11/2006 | CONTACTED IN PERSON |
08/11/2006 | NOTICE OF VIOLATION ISSUED |
10/30/2006 | VIOLATION CLOSED |